Unit of competency details

UETDRDS025 - Draft and layout street lighting system (Release 1)

Summary

Usage recommendation:
Current
Mapping:
MappingNotesDate
Supersedes UETDRDS010 - Draft and layout a power system street lighting system 13/Oct/2022

Release Status:
Current
Releases:
ReleaseRelease date
1 1 (this release) 14/Oct/2022


Classifications

SchemeCodeClassification value
ASCED Module/Unit of Competency Field of Education Identifier 031311 Powerline Installation And Maintenance  

Classification history

SchemeCodeClassification valueStart dateEnd date
ASCED Module/Unit of Competency Field of Education Identifier 031311 Powerline Installation And Maintenance  18/Nov/2022 
The content being displayed has been produced by a third party, while all attempts have been made to make this content as accessible as possible it cannot be guaranteed. If you are encountering issues following the content on this page please consider downloading the content in its original form

Unit of competency

Modification History

Release 1. This is the first release of this unit of competency in the UET Transmission, Distribution and Rail Sector Training Package Release 4.0.

Application

This unit includes the skills and knowledge required to draft and layout a street lighting system in the electricity supply industry (ESI).

It includes factors affecting external lighting design, calculation of light output and illuminance, and special lighting situations.

It also includes use of manuals and diagrams, and the fundamentals of surveying and computer-aided drafting.

The application of the skills and knowledge described in this unit may require a licence/registration to practice in the workplace.

Other conditions may also apply under state and territory legislative and regulatory licensing requirements which must be confirmed prior to commencing this unit.

Pre-requisite Unit

UEECD0007 Apply work health and safety regulations, codes and practices in the workplace

UEECD0044 Solve problems in multiple path circuits

UEECD0046 Solve problems in single path circuits

UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications

UEEEL0020 Solve problems in low voltage a.c. circuits

UEEEL0021 Solve problems in magnetic and electromagnetic devices

UETDREL005 Work safely in the vicinity of live electrical apparatus

Competency Field

Design

Unit Sector

Not applicable.

Elements and Performance Criteria

ELEMENTS 

PERFORMANCE CRITERIA 

Elements describe the essential outcomes.

Performance criteria describe the performance needed to demonstrate achievement of the element.

1  

Prepare to draft and layout street lighting system 

1.1 

Project requirements are determined

1.2 

Draft and layout specifications are determined in accordance with workplace requirements

1.3 

Tools, equipment and personal protective equipment (PPE) required for site inspections are determined, obtained and confirmed in working order

1.4 

Requirements for site inspections are determined in accordance with workplace requirements

1.5 

Work is prioritised and sequenced for completion in accordance with workplace requirements

2 

Draft and layout street lighting system 

2.1 

Site inspection is performed

2.2 

Street lighting system is drafted and laid out in accordance with workplace requirements

2.3 

Sustainable energy principles are used to evaluate and determine best outcomes in accordance with workplace requirements

2.4 

Environmental sustainability principles are used to evaluate and determine best outcomes in accordance with workplace requirements

2.5 

Draft and layout are checked for compliance against legislation, regulations, standards and codes of practice

2.6 

Health and safety risks are identified and minimised or eliminated by using safety and control measures in the design process

2.7 

Quality checks of work are undertaken in accordance with workplace requirements

3 

Complete work and documentation 

3.1 

Completed work is checked against customer and workplace requirements

3.2 

Work records, reports and documentation are completed, approved and appropriate personnel notified in accordance with workplace requirements

Foundation Skills

Foundation skills essential to performance are explicit in the performance criteria of this unit of competency.

Range of Conditions

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UET Transmission, Distribution and Rail Sector Training Package Companion Volume Implementation Guide.

Unit Mapping Information

This unit replaces and is not equivalent to UETDRDS010 Draft and layout a power system street lighting system.

Links

Companion Volume Implementation Guides are found in VETNet - https://vetnet.gov.au/Pages/TrainingDocs.aspx?q=229bace1-b7bc-4653-9300-dffb13ecfad7

 

Assessment requirements

Modification History

Release 1. This is the first release of this unit of competency in the UET Transmission, Distribution and Rail Sector Training Package Release 4.0.

Performance Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria on at least two (2) separate occasions and include:

  • drafting and laying out two (2) street lighting systems, including:
  • specifications
  • requirements for site inspection
  • sustainable energy principles and practices
  • compliance against legislation, regulations, standards and codes of practice, project and workplace requirements
  • identifying, minimising or eliminating health and safety risks by using safety and control measures
  • applying environmental sustainability principles
  • obtaining, inspecting and using relevant personal protective equipment (PPE) for site inspection
  • prioritising and sequencing work for completion in accordance with workplace requirements
  • performing at least one (1) site inspection
  • performing ongoing quality checks of work in accordance with workplace requirements
  • checking final design against project and workplace requirements
  • completing relevant work records, reports and documentation.

Knowledge Evidence

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements and performance criteria and include knowledge of:

  • street lighting system, draft and layout, including:
  • project requirements
  • design specifications
  • hazard, risk assessment and risk control requirements, including potential hazards
  • types and application of PPE
  • site inspections
  • prioritisation and sequencing of work for completion
  • application of environmental sustainability principles and practices
  • application of sustainable energy principles and practices
  • compliance with legislation, regulations, standards, codes of practice, and project and workplace requirements
  • work records, reports and documentation
  • manuals, diagrams and drawings
  • public lighting principles, including:
  • light design layout
  • electromagnetic spectrum
  • principles of colour
  • behaviour of light
  • factors that affect illumination
  • tools, equipment, and techniques used for installation, maintenance, and testing
  • types and function of lanterns/luminaires/lamps, control equipment, poles and associated hardware used for street lighting
  • types of street lighting components and circuits
  • factors affecting external lighting design
  • calculation of light output and illuminance
  • rated life of luminaries
  • special lighting situations, including security lighting, hazardous street locations and emergency lighting
  • principles of surveying
  • principles of computer-aided drafting.

Assessment Conditions

Assessors must hold credentials specified within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must satisfy the Principles of Assessment and Rules of Evidence and all regulatory requirements included within the Standards for Registered Training Organisations current at the time of assessment.

Assessment must occur in workplace operational situations where it is appropriate to do so.

Where this is not appropriate, assessment must occur in simulated conditions involving realistic and authentic activities that replicate operational workplace conditions.

Assessment processes and techniques must be appropriate to the language, literacy and numeracy requirements of the work being performed and the needs of the candidate.

Resources for assessment must include access to:

  • relevant and appropriate materials, tools, facilities, equipment and PPE currently used in industry to undertake drafting and layout of a street lighting system.
  • applicable documentation, including workplace procedures, relevant industry standards, equipment specifications, regulations, codes of practice and operation manuals.

Links

Companion Volume Implementation Guides are found in VETNet - https://vetnet.gov.au/Pages/TrainingDocs.aspx?q=229bace1-b7bc-4653-9300-dffb13ecfad7