Modification History
Not Applicable
Unit Descriptor
Unit Descriptor |
1 ) 1 .1 ) Descriptor |
This unit covers the setting-up and adjusting of RF transmission and reception systems for optimum performance. It encompasses safe working practices, signal testing and analysis, adjusting equipment, following procedures and documenting. |
Application of the Unit
Application of the Unit |
4 ) |
This unit is intended for competency development entry-level employment based programs incorporated in approved contracts of training or approved training programs. It may be used to augment previously acquired competencies. |
Licensing/Regulatory Information
1 .2 ) License to practice |
The skills and knowledge described in this unit do not require a license to practice in the workplace provided equipment is not connected to installation wiring at voltage above 50 V a.c. or 120 V d.c. However, practice in this unit is subject to regulations directly related to occupational health and safety and where applicable contracts of training such as apprenticeships. Note: |
Pre-Requisites
Prerequisite Unit (s ) |
2 ) |
2 .1 ) Competencies |
|
Granting competency in this unit shall be made only after competency in the following unit(s) has/have been confirmed. UEENEEH072C Find and repair faults in the RF sections of electronic apparatus For the full prerequisite chain details for this unit please refer to Table 2 in Volume 1, Part 2 |
Employability Skills Information
Employability Skills |
3 ) This unit contains Employability Skills The required outcomes described in this unit of competency contain applicable facets of Employability Skills. The Employability Skills Summary of the qualification in which this unit of competency is packaged will assist in identifying Employability Skill requirements. |
Elements and Performance Criteria Pre-Content
6 ) Elements describe the essential outcomes of a unit of competency |
Performance criteria describe the required performance needed to demonstrate achievement of the Element. Assessment of performance is to be consistent with the evidence guide. |
Elements and Performance Criteria
ELEMENT |
PERFORMANCE CRITERIA |
||
1 |
Prepare to set-up process measuring instruments. |
1.1 |
OHS procedures for a given work area are identified, obtained and understood. |
1.2 |
Established OHS risk control measures and procedures are followed in preparation for the work. |
||
1.3 |
Safety hazards that have not previously been identified are noted and established risk control measures are implemented. |
||
1.4 |
Appropriate personnel are consulted to ensure the work is co-ordinated effectively with others involved on the work site. |
||
1.5 |
Measurement parameters are identified by reviewing transmission/reception requirements and equipment manufacturer's instructions. |
||
1.6 |
Tools, equipment and testing devices needed for the work are obtained in accordance with established procedures and checked for correct operation and safety. |
||
1.7 |
Preparatory work is checked to ensure no unnecessary damage has occurred and complies with requirements. |
||
1.8 |
The need to test or measure live is determined in strict accordance with OHS requirements and when necessary conducted within established safety procedures. |
||
1.9 |
Circuits are checked as being isolated where necessary in strict accordance OHS requirements and procedures. |
||
2 |
Set-up process measuring instruments. |
2.1 |
OHS risk control measures and procedures for carrying out the work are followed. |
2.2 |
Testing/measuring devices are connected and set up in accordance with requirements for a particular control system. |
||
2.3 |
Measuring instruments are set up and adjusted in accordance with transmission/reception requirements and equipment manufacturer's instructions. |
||
2.4 |
Adjustments are made to provide optimum transmission/reception performance within regulatory requirements. |
||
2.5 |
Decisions for dealing with unexpected situations are made from discussions with appropriate persons and job specifications and requirements. |
||
2.6 |
Methods for dealing with unexpected situations are selected on the basis of safety and specified work outcomes. |
||
2.7 |
Setting-up is carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services and using sustainable energy principles. |
||
3 |
Completion and report set-up activities. |
3.1 |
OHS risk control work completion measures and procedures are followed. |
3.2 |
Work site is cleaned and made safe in accordance with established procedures. |
||
3.3 |
Adjustment settings are documented and an appropriate person or persons notified in accordance with established procedures. |
Required Skills and Knowledge
REQUIRED SKILLS AND KNOWLEDGE |
||
7 ) This describes the essential skills and knowledge and their level, required for this unit. |
||
Evidence shall show that knowledge has been acquired of safe working practices and commissioning commercial radio frequency (RF) transmission and reception systems. All knowledge and skills detailed in this unit should be contextualised to current industry practices and technologies. The extent of the essential knowledge and associated skills (EKAS) required is given in Volume 2 - Part 2.2 EKAS. It forms an integral part of this unit. |
||
2.10.8 |
Electronic communications, transmission lines |
|
2.10.9 |
Electronic communications, antennas and wave propagation |
|
2.10.19 |
Electronic communications, commissioning process |
|
2.11.7.2 |
Advanced electronics testing and measuring devices and techniques |
Evidence Guide
EVIDENCE GUIDE |
|||
9 ) The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package. . The Evidence Guide forms an integral part of this unit. It must be used in conjunction with all parts of the unit and performed in accordance with the Assessment Guidelines of this Training Package. |
|||
Overview of Assessment |
9 .1 ) Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the Industry-preferred model for apprenticeships. However, where summative (or final) assessment is used it must include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. It is recognised that, in some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accord with industry and regulatory policy. Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed. The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Sources of evidence need to be 'rich' in nature to minimise error in judgment. Activities associated with normal everyday work influence decisions about how/how much the data gathered will contribute to its 'richness'. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practised. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package. |
||
Critical aspects of evidence required to demonstrate competency in this unit |
9 .2 ) Before the critical aspects of evidence are considered all prerequisites shall be met. |
||
Evidence for competence in this unit shall be considered holistically. Each Element and associated performance criteria shall be demonstrated on at least two occasions in accordance with the 'Assessment Guidelines - UEE07'. Evidence shall also comprise:
|
|||
|
|||
|
|||
|
|||
A |
Identifying measurement parameters. |
||
B |
Setting-up and adjusting in accordance with transmission/reception requirements and equipment manufacturer's instructions. |
||
C |
Documenting adjustment settings with established procedures. |
||
D |
Dealing with unplanned events by drawing on essential knowledge and skills to provide appropriate solutions incorporated in a holistic assessment with the above listed items. |
||
Note: |
|||
Context of and specific resources for assessment |
9 .3 ) This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
These should be part of the formal learning/assessment environment. Note: Where simulation is considered a suitable strategy for assessment, conditions must be authentic and as far as possible reproduce and replicate the workplace and be consistent with the approved industry simulation policy. |
||
The resources used for assessment should reflect current industry practices in relation to commissioning commercial radio frequency (RF) transmission and reception systems. |
|||
Method of assessment |
9 .4 ) This unit shall be assessed by methods given in Volume 1, Part 3 'Assessment Guidelines'. Note: |
||
Concurrent assessment and relationship with other units |
9 .5 ) |
||
There are no concurrent assessment recommendations for this unit. |
|||
The critical aspects of occupational health and safety covered in unit UEENEEE001B and other discipline specific occupational health and safety units shall be incorporated in relation to this unit. |
Range Statement
RANGE STATEMENT |
8 ) This relates to the unit as a whole providing the range of contexts and conditions to which the performance criteria apply. It allows for different work environments and situations that will affect performance. |
This unit shall be demonstrated in relation to setting-up and adjusting a representative range of two different types of commercial radio frequency (RF) transmission and reception systems. |
Generic terms used throughout this Vocational Standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms that apply are given in Volume 2, Part 2.1. |
Unit Sector(s)
Not Applicable
Competency Field
2 .2 ) Literacy and numeracy skills Participants are best equipped to achieve competency in this unit if they have reading, writing and numeracy skills indicated by the following scales. Description of each scale is given in Volume 2, Part 3 'Literacy and Numeracy' |
|||||
Reading |
3 |
Writing |
3 |
Numeracy |
3 |
Custom Content Section
Competency Field |
5 ) |
Electronics |