Modification History
Release |
Action |
Core/Elective |
Details |
Points |
2 |
Update |
Group A |
BSBWHS501A Ensure a safe workplace |
60 |
2 |
Update |
Group A |
Update to the latest release LGAWORK404A – Manage a civil works project |
80 |
Description
Scope: Those gaining this qualification will be able to complete work function such as development of operational procedures and systems, manage the start up and shut down of boilers and turbines, hydro plant, gas turbines. Implementation of safe working practices and environmental procedures. Management and supervision of others and coordination of work activities of individuals and/or teams. |
Pathways Information
Not applicable.
Licensing/Regulatory Information
Not applicable.
Entry Requirements
Not applicable.
Employability Skills Summary
Not applicable.
Packaging Rules
Completion requirements: The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
|
||
Core Competency Standard Units All core competency standard units to be achieved |
Weighting Points |
|
UEENEEE117A |
Implement and monitor energy sector OHS policies and procedures |
20 |
UEENEEE101A |
Apply Occupational Health and Safety regulations, codes and practices in the workplace |
20 |
UEPOPS202B |
Apply Quality Systems to Work |
20 |
UEPOPS337B |
Maintain Quality Systems within the Team |
20 |
UEPOPS301B |
Conduct Single Energy Source Isolation Procedures for procedures for a Permit to Work |
40 |
UEPOPS402B |
Conduct Multiple Energy Source Isolation Procedures for procedures for a Permit to Work |
40 |
UEPOPS403B |
Coordinate Permit to Work System |
40 |
UEPOPS405B |
Operate and Monitor AC Electrical Systems |
30 |
UEPOPS406B |
Operate and Monitor DC Electrical Systems |
30 |
UEPOPS417B |
Monitor and Implement Environmental Plans and Procedures |
20 |
UEPOPS342B |
Interpret and Analyse Single Operation Protection Devices |
60 |
UEPOPS426B |
Interpret and Analyse Multi-Operation Protection Devices |
40 |
UEPOPS439B |
Plan and Organise Work |
30 |
UEPOPS440B |
Coordinate Team Activities |
30 |
UEPOPS454A |
Coordinate response to critical incidents |
30 |
UEPOPS457A |
Control electrical energy production |
40 |
UEPOPS501B |
Manage Occupational Health and Safety Policy and Procedures |
40 |
UEPOPS502B |
Manage Permit to Work System |
40 |
UEPOPS509B |
Manage Quality Control Procedures |
40 |
UEPOPS513B |
Manage Operational Crisis to Maintain/Restore Power System Integrity |
60 |
Total points in core |
690 |
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 910 points from the following groups: |
|||
Group |
Minimum points |
Maximum points |
|
A |
Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 5. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. |
0 |
270 |
B |
Qualification Electives You may select units from this group for qualification completion. |
0 |
490 |
C |
Qualification Electives You may select units from this group for qualification completion. |
0 |
180 |
D |
Qualification Electives You may select all your elective units from this Group |
240 |
910 |
Group A - Imported and Common Elective Units. Complete units to a maximum weighting of 270 points |
Weighting Points |
|
BSBCUS501C |
Manage quality customer service |
40 |
BSBINM501A |
Manage an information or knowledge management system |
50 |
BSBINN502A |
Build and sustain an innovative work environment |
50 |
BSBLED501A |
Develop a workplace learning environment |
60 |
BSBMGT502B |
Manage people performance |
70 |
BSBMGT515A |
Manage operational plan |
60 |
BSBMGT516C |
Facilitate continuous improvement |
60 |
BSBWHS501A |
Ensure a Safe Workplace |
60 |
BSBWOR501B |
Manage personal work priorities and professional development |
60 |
BSBWOR502B |
Ensure team effectiveness |
60 |
LGAWORK404A |
Manage a civil works project |
80 |
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 5. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, Page 10, UEP12 ESI Generation Sector Training Package, Part1.1.00 |
Up to 270 points |
Group B Qualification Electives. Complete units to a maximum weighting of 490 points |
Weighting Points |
|
UEPOPS304B |
Make and Spread a Stockpile |
40 |
UEPOPS305B |
Operate & Monitor Briquette Coal Cooling Plant |
40 |
UEPOPS306B |
Operate & Monitor Briquette Coal Drying Plant |
40 |
UEPOPS307B |
Operate & Monitor Briquette Coal Press Plant |
40 |
UEPOPS308B |
Perform Briquette Laboratory Tests |
40 |
UEPOPS309B |
Operate and Monitor Air Conditioning Equipment and Ventilation Systems |
20 |
UEPOPS310B |
Operate Bulk Coal Handling Plant |
40 |
UEPOPS311B |
Operate Fabric Filter Dust Collection Plant |
20 |
UEPOPS312B |
Operate and Monitor Fuel Supply |
20 |
UEPOPS313B |
Operate and Monitor Boiler Draught System |
40 |
UEPOPS314B |
Operate and Monitor Fuel Firing Plant (Gas or Oil) |
40 |
UEPOPS315B |
Operate and Monitor Fuel Firing Plant (Coal) |
40 |
UEPOPS316B |
Operate and Monitor Boiler Steam/Water Cycle |
40 |
UEPOPS317B |
Operate and Monitor Fixed Fire Protection Systems |
30 |
UEPOPS318B |
Operate and Monitor Compressed Gas Systems |
30 |
UEPOPS319B |
Operate and Monitor Gas Production Plant |
30 |
UEPOPS320B |
Operate and Monitor Compressed Air Systems |
30 |
UEPOPS321B |
Operate and Monitor Water Treatment Plant |
30 |
UEPOPS322B |
Operate and Monitor Alkalinity Reduction Plant |
30 |
UEPOPS323B |
Operate and Monitor Reverse Osmosis Plant |
30 |
UEPOPS324B |
Operate and Monitor Brine Concentrator Plant |
30 |
UEPOPS325B |
Operate and Monitor Water Quality Control Systems |
30 |
UEPOPS326B |
Operate and Monitor Oil Systems |
30 |
UEPOPS327B |
Monitor and Maintain Civil Assets |
30 |
UEPOPS328B |
Undertake Dam Safety Surveillance |
30 |
UEPOPS329B |
Operate and Monitor Auxiliary Steam Systems |
40 |
UEPOPS330B |
Operate and Monitor Heat Exchangers |
40 |
UEPOPS331B |
Operate and Monitor Water Systems (Condensate & Feedwater) |
40 |
UEPOPS332B |
Operate and Monitor Condensing and Cooling Water System |
40 |
UEPOPS333B |
Operate and Monitor H.R.S.G. Hot Gas Control System |
40 |
UEPOPS334B |
Operate and Monitor a Wind Generator |
60 |
UEPOPS335B |
Operate A Hydro Generator/Synchronous Condenser / Pump Unit |
60 |
UEPOPS336B |
Manage Operate and Monitor a Gas Turbine Unit |
60 |
UEPOPS338B |
Facilitate Effective Workplace Communication |
20 |
UEPOPS339B |
Operate and Monitor a Boiler Unit |
60 |
UEPOPS340B |
Operate and Monitor a Steam Turbine |
60 |
UEPOPS343B |
Operate Hydro-Electric Generating Plant and Auxiliary Equipment |
60 |
UEPOPS344B |
Conduct Water Conveyance and Control |
30 |
UEPOPS345B |
Implement Dam Safety Surveillance Procedures |
30 |
UEPOPS346B |
Conduct Non-Routine Operational Testing |
60 |
UEPOPS347B |
Operate and Monitor Supervisory, Control and Data Acquisition Systems |
40 |
UEPOPS349B |
Operate H.V. Primary Switchgear |
40 |
UEPOPS351B |
Operate H.V. Condition Changing Apparatus |
60 |
UEPOPS352B |
Conduct Operational Checks on In-Service Mechanical Plant |
40 |
UEPOPS354B |
Operate and Monitor Dual Fuel-Firing Plant |
80 |
UEPOPS355B |
Monitor the Implementation of Under Frequency Load Shedding |
60 |
UEPOPS356B |
Apply Environmental and Sustainable Energy Procedures |
20 |
UEPOPS357B |
Operate H.V. Secondary Switchgear |
40 |
UEPOPS358A |
Monitor and Maintain Wind Farm Civil Assets |
40 |
UEPOPS359A |
Monitor Climatic Conditions for Renewable Energy Production |
40 |
UEPOPS360A |
Operate and Monitor a Hydro Turbine |
60 |
UEPOPS361A |
Operate and Monitor Hydro Plant Auxiliary Systems |
60 |
UEPOPS362A |
Operate and Monitor Generator/Alternator |
60 |
UEPOPS364A |
Ensure Compliance with Occupational Health and Safety policy and procedures |
20 |
UEPOPS368A |
Operate manual systems |
30 |
UEPOPS369A |
Respond to a critical incident |
40 |
UEPOPS370A |
Facilitate the use of contingency plans |
60 |
UEPOPS371A |
Carry out operational checks on in-service electrical plant |
40 |
Group C Qualification Electives Complete units to a maximum weighting of 180 points |
Weighting Points |
|
UEPOPS404B |
Coordinate First Response Team Operation |
20 |
UEPOPS407B |
Start and Run Up A Gas Turbine |
60 |
UEPOPS408B |
Shut Down a Gas Turbine |
60 |
UEPOPS409B |
Start-Up A Boiler Unit |
60 |
UEPOPS410B |
Shut Down A Boiler Unit |
60 |
UEPOPS411B |
Run Up A Steam Turbine |
60 |
UEPOPS412B |
Undertake Operations Commissioning / Decommissioning |
30 |
UEPOPS413B |
Coordinate Operational Strategies for Power Production |
20 |
UEPOPS414B |
Perform Risk Analysis of Generation Plant |
20 |
UEPOPS416B |
Monitor the Implementation of the Enterprise’s Production / Maintenance Quality Control procedures |
20 |
UEPOPS419B |
Shut down a steam turbine |
60 |
UEPOPS420B |
Coordinate the Network/System |
40 |
UEPOPS422B |
Schedule Generation |
40 |
UEPOPS423B |
Plan a Scheduled Outage |
40 |
UEPOPS424B |
Coordinate Local H.V. Networks |
40 |
UEPOPS425B |
Produce Maintenance Plans For Generation Production Plant |
40 |
UEPOPS428B |
Develop H.V. Switching Programs |
40 |
UEPOPS430B |
Control Permit to Work Operations |
30 |
UEPOPS431B |
Collect and Analyse Hydrological and Meteorological Data |
20 |
UEPOPS432B |
Start up a Heat Recovery Steam Generator Unit |
30 |
UEPOPS433B |
Operate and Monitor a Heat Recovery Steam Generator Unit |
20 |
UEPOPS434B |
Shutdown an Heat Recovery Steam Generator Unit |
30 |
UEPOPS435B |
Operate and Monitor Flue Gas NOx Mitigation Systems |
30 |
UEPOPS437B |
Manage System Re-Start |
40 |
UEPOPS441B |
Operate and Monitor System Equipment |
30 |
UEPOPS442B |
Monitor and Co-ordinate the Operation of a Combined Cycle Gas Turbine Unit |
60 |
UEPOPS443A |
Coordinate Wind Farm Operations |
40 |
UEPOPS444A |
Start and Run-up a Hydro Turbine |
60 |
UEPOPS445A |
Shut Down a Hydro Turbine |
60 |
UEPOPS446A |
Operate and monitor hydro unit control and protection systems |
80 |
UEPOPS447A |
Coordinate photovoltaic solar power plant operations |
60 |
UEPOPS450A |
Coordinate effective workplace communication |
40 |
UEPOPS451A |
Coordinate the use of contingency plans |
40 |
UEPOPS452A |
Conduct operational checks and carry out corrective action on in-service electrical plant |
40 |
UEPOPS456A |
Perform switching to a switching program |
30 |
UEPOPL001A |
Licence to operate a steam turbine |
60 |
UEPOPL002A |
Licence to operate a reciprocating steam engine |
60 |
Group D Qualification Electives At least 240 points to be achieved from this group. You may select all your elective units from this Group |
Weighting Points |
|
UEPOPS505B |
Produce maintenance strategies for generation production plant |
80 |
UEPOPS507B |
Conduct Project Management |
60 |
UEPOPS508B |
Manage commissioning/ decommissioning |
80 |
UEPOPS510B |
Monitor Power Generation Plant Reliability |
60 |
UEPOPS511B |
Tune Process Plant and Equipment |
60 |
UEPOPS512B |
Manage the Network/System |
80 |
UEPOPS514B |
Control hydro generation/pumping |
60 |
UEPOPS515B |
Coordinate Power Generation |
40 |
UEPOPS520A |
Evaluate cost estimations and initiate appropriate solutions |
40 |
UEPOPS523A |
Manage critical incidents |
60 |
UEPOPS524A |
Evaluate the scheduling of generation |
60 |
UEPOPS525A |
Coordinate and direct switching program |
60 |
UEPOPS526A |
Coordinate electrical energy production |
60 |
UEPOPS527A |
Manage first response team |
40 |
UEPOPS528A |
Manage environmental management systems |
40 |
UEPOPS529A |
Manage operational strategies for power production |
80 |
Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.
END OF QUALIFICATION
Custom Content Section
Not applicable.