Modification History
Release |
Action |
Core/Elective |
Details |
Points |
2 |
Edit |
Included Group B and C to Elective Competency Standard Units table. |
4 |
Edit |
Core |
Correct title of UEENEEE101A - Apply Occupational Health and Safety regulations, codes and practices in the workplace |
20 |
4 |
Edit |
Core |
Correct title of UEENEEE102A - Fabricate, assemble and dismantle utilities industry components |
40 |
4 |
Edit |
Core |
Correct title of UEENEEE124A - Compile and produce an energy sector detailed report |
60 |
4 |
Edit |
Core |
Correct title of UEENEEJ102A - Prepare and connect refrigerant tubing and fittings |
30 |
4 |
Edit |
Elective |
Correct title of UEENEED101A - Use computer applications relevant to a workplace |
20 |
4 |
Edit |
Elective |
Correct title of UEENEEG131A - Evaluate performance of low voltage electrical apparatus |
40 |
4 |
Edit |
Elective |
Correct title of UEENEEI116A - Assemble, enter and verify operating instructions in microprocessor equipped devices |
20 |
4 |
Edit |
Elective |
Correct title of UEENEEJ178A - Apply safety awareness and legal requirements for ammonia refrigerant |
10 |
Description
Scope
This qualification provides competencies to select, install, commission, maintain and diagnose faults/malfunctions on refrigeration systems and equipment that apply to commercial food storage and preservation and air conditioning and air distribution equipment and special applications and associated electrical systems. It includes ERAC requirements for an ‘Electrician’s licence’ and regulatory requirements for purchasing and handling refrigerants.
Pathways Information
Not applicable.
Licensing/Regulatory Information
Not applicable.
Entry Requirements
Not applicable.
Employability Skills Summary
Not applicable.
Packaging Rules
Completion requirements
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- All the Core competency standard units, defined in the Core Competency Standard Units table below and
- A combination of Elective competency standard units to achieve a total weighting of 80 points in accordance with the Elective Competency Standard Units table below.
Note: 1 UEENEEG105A - Those holding an ‘Unrestricted Electricians Licence or equivalent issued in an Australian State or Territory meets the requirements of this unit and its pre-requisite requirements.
Note: 2. UEENEEJ109A - Those holding an ‘Certificate III in Refrigeration and Air-conditioning trade qualification or equivalent" meet the requirements of this unit and its pre-requisite requirements.
Core Competency Standard Units All Core competency standard units to be achieved |
Weighting Points |
|
UEENEEE038B |
Participate in development and follow a personal competency development plan |
20 |
UEENEEE084A |
Write specifications for electrotechnology engineering projects |
40 |
UEENEEE101A |
Apply Occupational Health and Safety regulations, codes and practices in the workplace |
20 |
UEENEEE102A |
Fabricate, assemble and dismantle utilities industry components |
40 |
UEENEEE104A |
Solve problems in d.c. circuits |
80 |
UEENEEE105A |
Fix and secure electrotechnology equipment |
20 |
UEENEEE107A |
Use drawings, diagrams, schedules, standards, codes and specifications |
40 |
UEENEEE117A |
Implement and monitor energy sector OHS policies and procedures |
20 |
UEENEEE124A |
Compile and produce an energy sector detailed report |
60 |
UEENEEE137A |
Document and apply measures to control OHS risks associated with electrotechnology work |
20 |
UEENEEG006A |
Solve problems in single and three phase low voltage machines |
80 |
UEENEEG033A |
Solve problems in single and three phase low voltage electrical apparatus and circuits |
60 |
UEENEEG063A |
Arrange circuits, control and protection for general electrical installations |
40 |
UEENEEG101A |
Solve problems in electromagnetic devices and related circuits |
60 |
UEENEEG102A |
Solve problems in low voltage a.c. circuits |
80 |
UEENEEG103A |
Install low voltage wiring and accessories |
20 |
UEENEEG104A |
Install appliances, switchgear and associated accessories for low voltage electrical installations |
20 |
UEENEEG105A |
Verify compliance and functionality of low voltage general electrical installations |
40 |
UEENEEG106A |
Terminate cables, cords and accessories for low voltage circuits |
40 |
UEENEEG107A |
Select wiring systems and cables for low voltage general electrical installations |
60 |
UEENEEG108A |
Trouble-shoot and repair faults in low voltage electrical apparatus and circuits |
40 |
UEENEEG109A |
Develop and connect electrical control circuits |
80 |
UEENEEJ102A |
Prepare and connect refrigerant tubing and fittings |
30 |
UEENEEJ103A |
Establish the basic operating conditions of vapour compression systems |
60 |
UEENEEJ104A |
Establish the basic operating conditions of air conditioning systems |
20 |
UEENEEJ106A |
Install refrigerant pipe work, flow controls and accessories |
60 |
UEENEEJ107A |
Install air conditioning and refrigeration systems, major components and associated equipment |
80 |
UEENEEJ108A |
Recover, pressure test, evacuate, charge and leak test refrigerants |
60 |
UEENEEJ109A |
Verify functionality and compliance of refrigeration and air conditioning installations |
20 |
UEENEEJ110A |
Select refrigerant piping, accessories and associated controls |
50 |
UEENEEJ111A |
Diagnose and rectify faults in air conditioning and refrigeration systems and components |
40 |
UEENEEJ113A |
Commission air conditioning and refrigeration systems |
40 |
UEENEEJ153A |
Find and rectify faults in motors and associated controls in refrigeration and air conditioning systems |
50 |
UEENEEJ170A |
Diagnose and rectify faults in air conditioning and refrigeration control systems |
70 |
UEENEEJ194A |
Solve problems in low voltage refrigeration circuits |
40 |
UEENEEK132A |
Develop strategies to address environmental and sustainability issues in the energy sector |
20 |
Total points in core |
1620 |
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 60 points from the following groups: |
|||
Group |
Minimum points |
Maximum points |
|
A |
Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 5. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. |
0 |
20 |
B |
Qualification Elective Units |
0 |
20 |
C |
Qualification Elective Units |
0 |
20 |
D |
Qualification Elective Units You may select all your elective units from this Group |
40 |
60 |
Group A – Imported and Common Elective Units You may complete units to a maximum weighting of 20 |
Weighting Points |
|
UEENEEC001B |
Maintain documentation |
20 |
UEENEEC002B |
Source and purchase material/parts for installation or service jobs |
20 |
UEENEEC003B |
Provide quotations for installation or service jobs |
20 |
UEENEEC010B |
Deliver a service to customers |
20 |
UEENEED101A |
Use computer applications relevant to a workplace |
20 |
UEENEEE009B |
Comply with scheduled and preventative maintenance program processes |
20 |
UEENEEE020B |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 5. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework |
Up to 20 points |
Group B – Qualification Elective Units You may complete units to a maximum weighting of 20 |
Weighting Points |
|
UEENEEG171A |
Install, set up and commission interval metering |
20 |
UEENEEI116A |
Assemble, enter and verify operating instructions in microprocessor equipped devices |
20 |
UEENEEI140A |
Plan the electrical installation of integrated systems |
20 |
UEENEEI141A |
Develop electrical integrated systems |
20 |
UEENEEJ118A |
Resolve problems in post mix refrigeration systems |
20 |
UEENEEJ119A |
Resolve problems in ice making systems |
20 |
UEENEEJ168A |
Maintain microbial control of refrigeration and air conditioning systems |
20 |
UEENEEJ174A |
Apply safety awareness and legal requirements for hydrocarbon refrigerants |
10 |
UEENEEJ178A |
Apply safety awareness and legal requirements for ammonia refrigerant |
10 |
Group C – Qualification Elective Units You may complete units to a maximum weighting of 20 |
Weighting Points |
|
UEENEEI142A |
Develop an electrical integrated system interface for access through a touch screen |
20 |
UEENEEI143A |
Develop access control of electrical integrated systems using logic-based programming tools |
20 |
UEENEEI144A |
Develop interfaces for multiple access methods to monitor, schedule and control an electrical integrated system |
20 |
UEENEEG076A |
Install and replace low voltage current transformer metering |
20 |
Group D – Qualification Elective Units You must complete units to a minimum weighting of 40 You may select all your elective units from this Group |
Weighting Points |
|
UEENEEG131A |
Evaluate performance of low voltage electrical apparatus |
40 |
UEENEEE110A |
Develop and implement energy sector maintenance programs |
60 |
UEENEEJ137A |
Evaluate and report on the indoor air quality of buildings |
40 |
Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.
3. Registered training organisations shall provide competency development advice in relation to any licensing requirements to practice that apply, or can contribute towards the qualification requirement, prior to establishing the competency development plan.
END OF QUALIFICATION
Custom Content Section
Not applicable.