Scope
This qualification provides competencies to select, install, commission, maintain and diagnose faults/malfunctions on refrigeration systems and equipment that apply to commercial food storage and preservation and air conditioning and air distribution equipment and special applications and associated electrical systems. It includes ERAC requirements for an 'Electrician's licence' and regulatory requirements for purchasing and handling refrigerants.
Pathways Information
Not Applicable
Licensing/Regulatory Information
Not Applicable
Entry Requirements
Not Applicable
Employability Skills Summary
Not Applicable
Packaging Rules
Completion requirements
The requirements for awarding this qualification are that the following are successfully achieved:
- All of the Core competency standard units;
- The required number of Stream Core competency standard units;
- The required number of Elective competency standard units as prescribed in the respective Schedule; and
- All the required pre-requisite competency standard units have been met as required.
- Note: 1 UEENEEG005B - Those holding an 'Unrestricted Electricians Licence or equivalent issued in an Australian State or Territory meet the requirements of this unit and its pre-requisite requirements.
- Note: 2. UEENEEJ009B - Those holding an 'Certificate III in Refrigeration and Air-conditioning trade qualification or equivalent" meet the requirements of this unit and its pre-requisite requirements.
Core Competency Standard Units All Core competency standard units to be achieved |
||
UEENEEE001B |
Apply OHS practices in the workplace |
|
UEENEEE002B |
Dismantle, assemble and fabricate electrotechnology components |
|
UEENEEE003B |
Solve problems in extra-low voltage single path circuits |
|
UEENEEE004B |
Solve problems in multiple path d.c. circuits |
|
UEENEEE005B |
Fix and secure equipment |
|
UEENEEE007B |
Use drawings, diagrams, schedules and manuals |
|
UEENEEE008B |
Lay wiring/cabling and terminate accessories for extra-low voltage circuits |
|
UEENEEE017B |
Implement and Monitor OHS Policies and Procedures |
|
UEENEEE024C |
Compile and produce an electrotechnology report |
|
UEENEEE033B |
Document occupational hazards and risks in electrical work |
|
UEENEEE036B |
Document occupational hazards and risks in refrigeration and air-conditioning |
|
UEENEEE038B |
Participate in development and follow a personal competency development plan |
|
UEENEEE084A |
Write specifications for electrotechnology engineering projects |
|
UEENEEG001B |
Solve problems in electromagnetic circuits |
|
UEENEEG002B |
Solve problems in single and three phase low voltage circuits |
|
UEENEEG003B |
Install wiring and accessories for low voltage circuits |
|
UEENEEG004B |
Install low voltage electrical apparatus and associated equipment |
|
UEENEEG005B |
Verify compliance and functionality of general electrical installations |
|
UEENEEG007B |
Select and arrange equipment for general electrical installations |
|
UEENEEG008B |
Find and repair faults in electrical apparatus and circuits |
|
UEENEEG009B |
Develop and connect control circuits |
|
UEENEEJ002B |
Prepare refrigeration tubing and fittings |
|
UEENEEJ003B |
Determine the basic operating conditions of vapour compression systems |
|
UEENEEJ004B |
Determine the basic operating conditions of air conditioning systems |
|
UEENEEJ006B |
Install pipework for refrigeration and air conditioning systems |
|
UEENEEJ007B |
Install refrigeration and air conditioning systems, major components and associated equipment |
|
UEENEEJ008B |
Recover, pressure and leak test, evacuate and charge refrigerants |
|
UEENEEJ009B |
Verify compliance and functionality of refrigeration and air conditioning installations |
|
UEENEEJ010B |
Select refrigeration pipe/tube, accessories and associated controls |
|
UEENEEJ011B |
Diagnose and rectify faults in refrigeration and air conditioning systems and components |
|
UEENEEJ013B |
Commission refrigeration and air conditioning systems |
|
UEENEEJ053B |
Find and rectify faults in appliance motors and associated controls |
|
UEENEEJ070B |
Diagnose and rectify faults in refrigeration and air conditioning control systems |
|
UEENEEP001B |
Disconnect and reconnect fixed wired electrical equipment connected to a Low Voltage supply |
|
UEENEEP002B |
Attach cords and plugs to electrical equipment for connection to a single phase 250 Volt supply |
|
UEENEEP003B |
Attach cords and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply |
|
UEENEEP007B |
Locate and rectify faults in electrical low voltage equipment following prescribed procedures |
|
Stream Core Competency Standard Units At least 1 of the following competency standard units to be achieved |
||
BSBMGT502B |
Manage people performance |
|
BSBINM501A |
Manage an information or knowledge management system |
|
BSBMGT516C |
Facilitate continuous improvement |
|
BSBINN502A |
Build and sustain an innovative work environment |
|
BSBWOR502B |
Ensure team effectiveness |
|
OR |
||
At least 4 of the following competency standard units to be achieved |
||
UEENEEC001B |
Maintain documentation |
|
UEENEEC002B |
Source and purchase material/parts for installation or service jobs |
|
UEENEEC003B |
Provide quotations for installation or service jobs |
|
UEENEEC010B |
Deliver a service to customers |
|
UEENEED001B |
Use basic computer applications relevant to a workplace |
|
UEENEEE009B |
Comply with scheduled and preventative maintenance program processes |
|
UEENEEE020B |
Provide basic instruction in the use of electrotechnology apparatus |
|
UEENEEK042A |
Participate in environmentally sustainable work practices |
|
UEENEEK045A |
Implement&monitor, policies&procedures for environmentally sustainable electrotech work practice |
Elective Competency Standard Units
In accordance with Schedule 5 which forms an integral part of this qualification, achieve a Unit Strand Total of at least 9.
Note : 1. Pre-requisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a pre-requisite pathway for the progression to achieve particular competencies or qualification at a higher level.
3. Registered training organisations shall provide competency development advice in relation to any licensing requirements to practice that apply, or can contribute towards the qualification requirement, prior to establishing the competency development plan.
END OF QUALIFICATION