Modification History
Release |
Action |
Core/Elective |
Details |
Points |
2 |
Update |
Group A |
BSBWHS501A Ensure a safe workplace |
60 |
3 |
Edit |
Core |
Correct weighting points of UEPOPS439B – Plan and organise work |
30 |
3 |
Edit |
Group C |
Correct weighting points of UEPOPS440B – Coordinate team activities |
30 |
Description
Scope : This qualification provides competencies to manufacture, fit, assemble, erect, operate, test, fault find, alter, repair electrical equipment, electronic, instrumentation systems, and includes electrical wiring work only if that work is associated with assembling, maintaining, terminating or altering the wiring between electrical components within a power generating plant or machinery. Development of maintenance schedules and project management. Implementation of safe working practices and environmental procedures. Management and supervision of others and coordination of work activities of individuals and/or teams. Electrical equipment means any appliance, article, accessory, wire, fitting, cable, conduit or apparatus that generates, uses, conveys or controls (or that is intended to generate, use, convey or control) electricity above extra low voltage. This qualification does not authorise the holder to install any electrical wiring systems within an electrical installation as prescribed by definitions contained in AS/NZS 3000. |
Pathways Information
Not applicable.
Licensing/Regulatory Information
Not applicable.
Entry Requirements
Not applicable.
Employability Skills Summary
Not applicable.
Packaging Rules
Completion requirements: The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
|
||
Core Competency Standard Units All core competency standard units to be achieved |
Weighting Points |
|
UEENEEE101A |
Apply Occupational Health and Safety regulations, codes and practices in the workplace |
20 |
UEENEEE102A |
Fabricate, dismantle, assemble utilities components |
40 |
UEENEEE104A |
Solve problems in d.c. circuits |
80 |
UEENEEE105A |
Fix and secure electrotechnology equipment |
20 |
UEENEEE107A |
Use drawings, diagrams, schedules, standards, codes and specifications |
40 |
UEENEEE117A |
Implement and monitor energy sector OHS policies and procedures |
20 |
UEENEEE137A |
Document and apply measures to control OHS risks associated with electrotechnology work |
20 |
UEENEEG006A |
Solve problems in single and three phase low voltage machines |
80 |
UEENEEG033A |
Solve problems in single and three phase low voltage electrical apparatus and circuits |
60 |
UEENEEG063A |
Arrange circuits, control and protection for general electrical installations |
40 |
UEENEEG101A |
Solve problems in electromagnetic devices and related circuits |
60 |
UEENEEG102A |
Solve problems in low voltage a.c circuits |
80 |
UEENEEG106A |
Terminate cables, cords and accessories for low voltage circuits |
40 |
UEENEEG108A |
Trouble-shoot and repair faults in low voltage electrical apparatus and circuits |
40 |
UEENEEG109A |
Develop and connect electrical control circuits |
80 |
UEPOPS337B |
Maintain Quality Systems within the Team |
20 |
UEPOPS338B |
Facilitate Effective Workplace Communications |
20 |
UEPOPS371A |
Carry out operational checks on in-service electrical plant |
40 |
UEPOPS417B |
Monitor and Implement Environmental Plans and Procedures |
20 |
UEPOPS430B |
Control permit to work operations |
20 |
UEPOPS439B |
Plan and Organise Work |
30 |
UEPOPS501B |
Manage Occupational Health and Safety Policy and Procedures |
40 |
UEPOPS507B |
Conduct Project Management |
60 |
UEPOPS509B |
Manage Quality Control Procedures |
40 |
Total points in core |
1010 |
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 590 points from the following groups: |
|||
Group |
Minimum points |
Maximum points |
|
A |
Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 5. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. |
0 |
270 |
B |
Qualification Electives You may select units from this group for qualification completion. |
0 |
180 |
C |
Qualification Electives You may select units from this group for qualification completion. |
0 |
240 |
D |
Qualification Electives You may select all your elective units from this Group |
180 |
540 |
Group A - Imported and Common Elective Units . Complete units to a maximum weighting of 270 points |
Weighting Points |
|
BSBWOR501B |
Manage personal work priorities and professional development |
60 |
BSBMGT502B |
Manage people performance |
70 |
BSBMGT515A |
Manage operational plan |
60 |
BSBINM501A |
Manage an information or knowledge management system |
50 |
BSBCUS501C |
Manage quality customer service |
40 |
BSBMGT516C |
Facilitate continuous improvement |
60 |
BSBINN502A |
Build and sustain an innovative work environment |
50 |
BSBLED501A |
Develop a workplace learning environment |
60 |
BSBWOR502B |
Ensure team effectiveness |
60 |
BSBWHS501A |
Ensure a Safe Workplace |
60 |
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 5. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, Page 10, UEP12 ESI Generation Sector Training Package, Part1.1.00 |
Up to 270 points |
Group B Qualification Electives. Complete units to a maximum weighting of 180 points |
Weighting Points |
|
UEPMNT319B |
Maintain and Test Fixed Fire Protection Systems |
20 |
UEPMNT345B |
Install electronic equipment |
40 |
UEPMNT346B |
Maintain electrical equipment |
40 |
UEPMNT347B |
Maintain complex electrical equipment |
60 |
UEPMNT348B |
Maintain electrical electronic equipment |
40 |
UEPMNT350B |
Modify electrical equipment |
40 |
UEPMNT351B |
Test and commission electrical equipment |
40 |
UEPMNT352B |
Test and commission electronic electrical equipment |
40 |
UEPMNT355B |
Install complex/electronic instrumentation equipment |
40 |
UEPMNT356B |
Maintain instrumentation equipment |
40 |
UEPMNT357B |
Diagnose and repair faults in instrumentation equipment |
60 |
UEPMNT358B |
Modify instrumentation equipment |
40 |
UEPMNT359B |
Test and Commission Instrumentation Systems |
40 |
UEPMNT361A |
Maintain Wind Turbine Mechanical Systems |
60 |
UEPMNT362A |
Maintain Wind Turbine Control Systems |
60 |
UEPMNT366A |
Maintain power plant inverter systems |
60 |
UEPOPS301B |
Conduct Single Energy Source Isolation Procedures for Permit to Work |
40 |
Group C Qualification Electives. Complete units to a maximum weighting of 240 points |
Weighting Points |
|
UEENEEC005B |
Estimate electrotechnology projects |
40 |
UEENEEE124A |
Compile and produce an energy sector report |
60 |
UEPMNT410B |
Diagnose and Repair Faults in Electronic Equipment |
60 |
UEPMNT411B |
Diagnose and Repair Faults in Complex Electrical Equipment |
60 |
UEPMNT412B |
Modify Complex Electrical Equipment |
60 |
UEPMNT413B |
Modify Electronic Electrical Equipment |
60 |
UEPMNT414B |
Test and Commission Complex Electrical Equipment |
60 |
UEPMNT415B |
Diagnose and Repair Faults in Complex Refrigeration / Air Conditioning Equipment |
60 |
UEPMNT416B |
Overhaul Electrical Generators |
80 |
UEPMNT417B |
Inspect Electrical Generators and Diagnose Faults |
80 |
UEPMNT421B |
Conduct Technical Inspection of Process Plant and Equipment |
60 |
UEPMNT422B |
Conduct Performance Testing on Process Plant and Equipment |
60 |
UEPMNT424B |
Monitor Efficiency of Thermal Steam Cycle Power Plant |
60 |
UEPMNT425B |
Maintain Complex Instrumentation Equipment |
80 |
UEPMNT426B |
Maintain Electronic Instrumentation Equipment |
80 |
UEPMNT427B |
Diagnose and Repair Faults in Complex Instrumentation Equipment |
80 |
UEPMNT428B |
Modify Complex Instrumentation Equipment |
80 |
UEPMNT429B |
Modify Electronic Instrumentation Equipment |
80 |
UEPMNT430B |
Test and Commission Complex Instrumentation Equipment |
80 |
UEPMNT431B |
Test and Commission Electronic Instrumentation Equipment |
80 |
UEPOPS402B |
Conduct Multiple Energy Source Isolation Procedures for procedures for a Permit to Work |
40 |
UEPOPS440B |
Coordinate Team Activities |
30 |
Group D Qualification Electives. You must complete units to a minimum weighting of 180. You may select units to a maximum weighting of 540. |
Weighting Points |
|
UEPMNT501B |
Diagnose and Repair Faults in Electrical and Electronic Systems |
100 |
UEPMNT502B |
Test and Commission Electronic Electrical Systems |
100 |
UEPMNT503B |
Diagnose and Repair Faults in Instrumentation Systems |
100 |
UEPMNT504B |
Test and Commission Instrumentation Systems |
100 |
UEPOPS508B |
Manage Commissioning/Decommissioning |
80 |
UEPOPS511B |
Tune Process Plant and Equipment |
60 |
Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.
END OF QUALIFICATION
Custom Content Section