^

 
 

Qualification details

UEE62411 - Advanced Diploma of Engineering Technology - Air-conditioning and Refrigeration (Release 5)

Summary

Usage recommendation:
Superseded
Mapping:
MappingNotesDate
Supersedes and is equivalent to UEE60807 - Advanced Diploma of Refrigeration and Air-Conditioning - Technology 28/Jul/2011
Supersedes and is equivalent to UEE61910 - Advanced Diploma of Engineering Technology - Refrigeration and Air-conditioning 28/Jul/2011
Is superseded by and equivalent to UEE62420 - Advanced Diploma of Engineering Technology - Air Conditioning and Refrigeration 04/Oct/2020

Releases:
ReleaseRelease date
5 (this release) 17/Apr/2014
(View details for release 4) 14/Aug/2013
(View details for release 3) 06/Mar/2013
(View details for release 2) 16/Mar/2012
(View details for release 1) 29/Jul/2011

Units of competency

CodeSort Table listing Units of Competency by the Code columnTitleSort Table listing Units of Competency by the Title columnUsage RecommendationSort Table listing Units of Competency by the Usage Recommendation columnEssentialSort Table listing Units of Competency by the Essential column
UEENEEJ133A - Design industrial refrigeration systems and select componentsDesign industrial refrigeration systems and select componentsSupersededElective
UEENEEC003B - Provide quotations for installation or service jobsProvide quotations for installation or service jobsSupersededElective
UEENEED101A - Use computer applications relevant to a workplaceUse computer applications relevant to a workplaceDeletedElective
UEENEEJ178A - Apply safety awareness and legal requirements for ammonia refrigerantApply safety awareness and legal requirements for ammonia refrigerantSupersededElective
UEENEEE083A - Establish and follow a competency development plan in an electrotechnology engineering disciplineEstablish and follow a competency development plan in an electrotechnology engineering disciplineSupersededCore
UEENEEJ177A - Design hydrocarbon refrigerated systemsDesign hydrocarbon refrigerated systemsSupersededElective
UEENEEJ183A - Design secondary refrigerant systemsDesign secondary refrigerant systemsSupersededElective
UEENEEJ190A - Select basic commercial refrigeration system equipment, components and accessoriesSelect basic commercial refrigeration system equipment, components and accessoriesSupersededElective
UEENEEE124A - Compile and produce an energy sector detailed reportCompile and produce an energy sector detailed reportSupersededCore
UEENEEJ143A - Design complex air conditioning systems and select equipmentDesign complex air conditioning systems and select equipmentSupersededElective
Items per page 10 | 20 | 50 | 100
Displaying items 1 - 10 of 64

Classifications

SchemeCodeClassification value
ANZSCO Identifier 342111 Airconditioning And Refrigeration Mechanic 
ASCO (occupation type) Identifier 4312-01 Supervisor, Refrigeration And Airconditioning Mechanics 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 
Qualification/Course Level of Education Identifier 411 Advanced Diploma 
Taxonomy - Industry Sector N/A Airconditioning and Refrigeration 
Taxonomy - Occupation N/A Refrigeration and Air-conditioning Senior Technologist 

Classification history

SchemeCodeClassification valueStart dateEnd date
ANZSCO Identifier 342111 Airconditioning And Refrigeration Mechanic 07/Aug/2012 
ASCO (occupation type) Identifier 4312-01 Supervisor, Refrigeration And Airconditioning Mechanics 07/Aug/2012 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 07/Aug/2012 
Qualification/Course Level of Education Identifier 411 Advanced Diploma 21/Jul/2011 
The content being displayed has been produced by a third party, while all attempts have been made to make this content as accessible as possible it cannot be guaranteed. If you are encountering issues following the content on this page please consider downloading the content in its original form

Modification History

Release

Action

Core/Elective

Details

Points

3

Add

Group A

CPPBDN5013A Develop and collaborate on building information models for small-scale building design projects

100

3

Add

Group D

UEENEEE150A Undertake computations in an energy sector environment

120

3

Add

Group D

UEENEEE129A Solve electrotechnical engineering problems

60

3

Add

Group D

UEENEEK151A Develop effective engineering strategies for energy reduction in buildings

60

3

Edit

Edit Name to reflect correct Unit title

UEENEED104A Use engineering applications software on personal computers

40

5

Edit

Core

Correct title of UEENEEJ129A Establish heat loads for commercial refrigeration and/or air conditioning applications

80

5

Edit

Elective

Correct title of UEENEEK145A Implement and monitor energy sector environmental and sustainable policies and procedures

20

Description

Scope 

This qualification provides competencies to design and validate/evaluate refrigeration and air conditioning equipment and systems and provide technical advice/sales.

Pathways Information

Not Applicable

Licensing/Regulatory Information

Not Applicable

Entry Requirements

Not Applicable

Employability Skills Summary

Not Applicable

Packaging Rules

Completion requirements 

The requirements for granting this qualification will be met when competency is demonstrated and achieved for:

  • All the Core competency standard units, defined in the Core Competency Standard Units table below and
  • A combination of Elective competency standard units to achieve a total weighting of 800 points in accordance with the Elective Competency Standard Units table below.

Core Competency Standard Units  

All Core competency standard units to be achieved

Weighting Points 

UEENEED104A

Use engineering applications software on personal computers

40

UEENEEE080A

Apply industry and community standards to engineering activities

20

UEENEEE083A

Establish and follow a competency development plan in an electrotechnology engineering discipline

120

UEENEEE101A

Apply Occupational Health and Safety regulations, codes and practices in the workplace

20

UEENEEE102A

Fabricate, assemble and dismantle utilities industry components

40

UEENEEE107A

Use drawings, diagrams, schedules, standards, codes and specifications

40

UEENEEE124A

Compile and produce an energy sector detailed report

60

UEENEEE126A

Provide solutions to basic engineering computational problems

60

UEENEEE127A

Use advanced computational processes to provide solutions to energy sector engineering problems

80

UEENEEE129A

Solve electrotechnical engineering problems

60

UEENEEE137A

Document and apply measures to control OHS risks associated with electrotechnology work

20

UEENEEE146A

Identify effects of energy on machinery and materials in an energy sector environment

120

UEENEEJ069B

Plan refrigeration and air conditioning projects

60

UEENEEJ127A

Establish the thermodynamic parameters of refrigeration and air conditioning systems

80

UEENEEJ128A

Produce HVAC/R system design drawings

80

UEENEEJ129A

Establish heat loads for commercial refrigeration and/or air conditioning applications

80

UEENEEJ138A

Analyse vibration and noise in refrigeration and air conditioning systems

80

UEENEEJ164A

Analyse the operation of HVAC air and hydronic systems

80

UEENEEJ165A

Evaluate thermodynamic and fluid parameters of refrigeration systems

100

UEENEEJ192A

Analyse the psychrometric performance of HVAC/R systems

50

UEENEEJ193A

Analyse the thermodynamic performance of HVAC/R systems

50

UEENEEK132A

Develop strategies to address environmental and sustainability issues in the energy sector

20

Total points in core 

1360 

Elective Competency Standard Units 

Complete Elective units to achieve a total of weighting of 800 points from the following groups:

Group 

Minimum points 

Maximum points 

A 

Imported and Common Elective Units 

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 6. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

0

350

B 

Qualification Elective Units 

0

100

C 

Qualification Elective Units 

120

320

D 

Qualification Elective Units 

200

360

E 

Qualification Elective Units 

360

480

Group A – Imported and Common Electives Units 

You may complete units to a maximum weighting of 350

Weighting Points 

UEENEEC001B

Maintain documentation

20

UEENEEC002B

Source and purchase material/parts for installation or service jobs

20

UEENEEC003B

Provide quotations for installation or service jobs

20

UEENEEC010B

Deliver a service to customers

20

UEENEED101A

Use computer applications relevant to a workplace

20

UEENEEE020B

Provide basic instruction in the use of electrotechnology apparatus

20

BSBINM501A

Manage an information or knowledge management system

50

BSBINN502A

Build and sustain an innovative work environment

50

CPPBDN5013A

Develop and collaborate on building information models for small-scale building design projects

100

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 6. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework

Up to 350 points

Group B – Qualification Elective Units 

You may complete units to a maximum weighting of 100

Weighting Points 

UEENEEJ103A

Establish the basic operating conditions of vapour compression systems

60

UEENEEJ110A

Select refrigerant piping, accessories and associated controls

50

UEENEEJ174A

Apply safety awareness and legal requirements for hydrocarbon refrigerants

10

UEENEEJ178A

Apply safety awareness and legal requirements for ammonia refrigerant

10

UEENEEJ184A

Apply safety awareness and legal requirements for Carbon Dioxide refrigerant

10

Group C – Qualification Elective Units  

You must complete units to a minimum weighting of 120 to a maximum of 320

Weighting Points 

UEENEEC005B

Estimate electrotechnology projects

40

UEENEEJ130A

Produce HVAC/R control system diagrams

40

UEENEEJ190A

Select basic commercial refrigeration system equipment, components and accessories

40

UEENEEJ191A

Select residential air conditioning system equipment, components and accessories

40

UEENEEK145A

Implement and monitor energy sector environmental and sustainable policies and procedures

20

Group D – Qualification Elective Units  

You must complete units to a minimum weighting of 200 to a maximum of 360

Weighting Points 

UEENEEC006B

Prepare tender submissions for electrotechnology projects

60

UEENEEE150A

Undertake computations in an energy sector environment

120

UEENEEJ132A

Design commercial refrigeration systems and select components

80

UEENEEJ133A

Design industrial refrigeration systems and select components

60

UEENEEJ134A

Design heating, ventilation and air conditioning (HVAC) systems and select components

60

UEENEEJ135A

Design control systems for refrigeration or heating, ventilation and air conditioning systems

80

UEENEEJ136A

Evaluate and report on building services energy management systems

80

UEENEEJ137A

Evaluate and report on the indoor air quality of buildings

40

UEENEEJ177A

Design hydrocarbon refrigerated systems

40

UEENEEJ181A

Design ammonia refrigerated systems

40

UEENEEJ183A

Design secondary refrigerant systems

40

UEENEEJ187A

Design carbon dioxide refrigerated systems

40

UEENEEK151A

Develop effective engineering strategies for energy reduction in buildings

60

Group E – Qualification Elective Units 

You must complete units to a minimum weighting of 360 to a maximum of 480

Weighting Points 

UEENEEC007B

Manage contract variations

40

UEENEEJ139A

Develop specifications and prepare drawings for HVAC/Refrigeration projects

60

UEENEEJ141A

Design complex commercial refrigeration systems and select equipment

40

UEENEEJ142A

Design complex industrial refrigeration systems and select equipment

40

UEENEEJ143A

Design complex air conditioning systems and select equipment

120

UEENEEJ144A

Design mechanical ventilation/exhaust systems and select equipment

40

UEENEEJ145A

Design hydronic systems and select equipment

80

UEENEEJ146A

Design complex control systems for refrigeration or heating, ventilation, air conditioning systems

80

UEENEEJ149A

Develop heat exchanger design specifications

80

UEENEEJ150A

Evaluate new and alternative technologies applicable to electrotechnology applications

40

Note:  

1. Pre-requisite pathways shall be identified and met for all elective units selected.

2. In selecting elective units considerations to career planning advice should be given to units that form part of a pre-requisite pathway for the progression to achieve particular competencies or qualification at a higher level.

3. Registered training organisations shall also provide information related to the relevant pathway(s) that may be taken to achieve paraprofessional status ("associate membership") with a professional engineering membership organisation.

END OF QUALIFICATION