^

 
 

Qualification details

UEE51211 - Diploma of Air-conditioning and Refrigeration Engineering (Release 4)

Summary

Usage recommendation:
Superseded
Mapping:
MappingNotesDate
Supersedes and is equivalent to UEE50607 - Diploma of Refrigeration and Air-Conditioning Engineering 28/Jul/2011
Supersedes and is equivalent to UEE50610 - Diploma of Refrigeration and Air-Conditioning Engineering 28/Jul/2011
Is superseded by and equivalent to UEE51220 - Diploma of Air Conditioning and Refrigeration Engineering 04/Oct/2020

Releases:
ReleaseRelease date
(View details for release 5) 17/Apr/2014
4 (this release) 14/Aug/2013
(View details for release 3) 06/Mar/2013
(View details for release 2) 16/Mar/2012
(View details for release 1) 29/Jul/2011

Replaced release

You are currently viewing the components related to release 4.
The current release is release 5View release 5 details.

Units of competency

CodeSort Table listing Units of Competency by the Code columnTitleSort Table listing Units of Competency by the Title columnUsage RecommendationSort Table listing Units of Competency by the Usage Recommendation columnEssentialSort Table listing Units of Competency by the Essential column
UEENEEJ133A - Design industrial refrigeration systems and select componentsDesign industrial refrigeration systems and select componentsSupersededElective
MEM30003A - Produce detailed engineering drawingsProduce detailed engineering drawingsDeletedElective
UEENEEJ179A - Repair and service ammonia refrigeration systemsRepair and service ammonia refrigeration systemsSupersededElective
UEENEEP025A - Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supplyAttach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supplySupersededCore
UEENEEJ182A - Repair and service secondary refrigeration systemsRepair and service secondary refrigeration systemsSupersededElective
UEENEEJ178A - Apply safety awareness and legal requirements for ammonia refrigerantApply safety awareness and legal requirements for ammonia refrigerantSupersededElective
MEM30001A - Use computer aided drafting systems to produce basic engineering drawingsUse computer aided drafting systems to produce basic engineering drawingsDeletedElective
UEENEEJ177A - Design hydrocarbon refrigerated systemsDesign hydrocarbon refrigerated systemsSupersededElective
UEENEEJ183A - Design secondary refrigerant systemsDesign secondary refrigerant systemsSupersededElective
UEENEEJ171A - Resolve problems in refrigerated beverage vending cabinetsResolve problems in refrigerated beverage vending cabinetsSupersededElective
Items per page 10 | 20 | 50 | 100
Displaying items 1 - 10 of 86

Classifications

SchemeCodeClassification value
ANZSCO Identifier 342111 Airconditioning And Refrigeration Mechanic 
ASCO (occupation type) Identifier 4312-11 Refrigeration And Airconditioning Mechanic 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 
Qualification/Course Level of Education Identifier 421 Diploma 
Taxonomy - Industry Sector N/A Airconditioning and Refrigeration 
Taxonomy - Occupation N/A Refrigeration and Air-conditioning Technical Officer 

Classification history

SchemeCodeClassification valueStart dateEnd date
ANZSCO Identifier 342111 Airconditioning And Refrigeration Mechanic 07/Aug/2012 
ASCO (occupation type) Identifier 4312-11 Refrigeration And Airconditioning Mechanic 07/Aug/2012 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 07/Aug/2012 
Qualification/Course Level of Education Identifier 421 Diploma 21/Jul/2011 
The content being displayed has been produced by a third party, while all attempts have been made to make this content as accessible as possible it cannot be guaranteed. If you are encountering issues following the content on this page please consider downloading the content in its original form

Modification History

Not Applicable

Description

Scope 

This qualification provides competencies to develop systems, select equipment, and commission, maintain and diagnose faults/malfunctions of refrigeration systems and equipment that apply to commercial food storage and preservation and air conditioning and air distribution equipment and special applications. It includes regulatory requirements for purchasing and handling refrigerants.

Note:  

The Ozone Protection and Synthetic Greenhouse Gas Legislation Amendment Bill 2003 apply to this qualification. Prior to planning the delivery of any training and/or assessment activities all legislative and regulatory requirements shall be identified and included.

Pathways Information

Not Applicable

Licensing/Regulatory Information

Not Applicable

Entry Requirements

Not Applicable

Employability Skills Summary

Not Applicable

Packaging Rules

Completion requirements 

The requirements for granting this qualification will be met when competency is demonstrated and achieved for:

  • All the Core competency standard units, defined in the Core Competency Standard Units table below and
  • A combination of Elective competency standard units to achieve a total weighting of 130 points in accordance with the Elective Competency Standard Units table below.

Note: UEENEEJ109A - Those holding an ‘Certificate III in Refrigeration and Air-conditioning trade qualification or equivalent" meet the requirements of this unit and its pre-requisite requirements.

Core Competency Standard Units  

All Core competency standard units to be achieved

Weighting Points 

UEENEED104A

Use engineering applications software on personal computers

40

UEENEEE038B

Participate in development and follow a personal competency development plan

20

UEENEEE101A

Apply Occupational Health and Safety regulations, codes and practices in the workplace

20

UEENEEE102A

Fabricate, assemble and dismantle utilities industry components

40

UEENEEE103A

Solve problems in ELV single path circuits

40

UEENEEE105A

Fix and secure electrotechnology equipment

20

UEENEEE107A

Use drawings, diagrams, schedules, standards, codes and specifications

40

UEENEEE117A

Implement and monitor energy sector OHS policies and procedures

20

UEENEEE124A

Compile and produce an energy sector detailed report

60

UEENEEE137A

Document and apply measures to control OHS risks associated with electrotechnology work

20

UEENEEJ102A

Prepare and connect refrigerant tubing and fitting

30

UEENEEJ103A

Establish the basic operating conditions of vapour compression systems

60

UEENEEJ104A

Establish the basic operating conditions of air conditioning systems

20

UEENEEJ106A

Install refrigerant pipe work, flow controls and accessories

60

UEENEEJ107A

Install air conditioning and refrigeration systems, major components and associated equipment

80

UEENEEJ108A

Recover, pressure test, evacuate, charge and leak test refrigerants

60

UEENEEJ109A

Verify functionality and compliance of refrigeration and air conditioning installations

20

UEENEEJ110A

Select refrigerant piping, accessories and associated controls

50

UEENEEJ111A

Diagnose and rectify faults in air conditioning and refrigeration systems and components

40

UEENEEJ113A

Commission air conditioning and refrigeration systems

40

UEENEEJ127A

Establish the thermodynamic parameters of refrigeration and air conditioning systems

80

UEENEEJ129A

Establish heat loads for commercial refrigeration and/or air conditioning applications

80

UEENEEJ153A

Find and rectify faults in motors and associated controls in refrigeration and air conditioning systems

50

UEENEEJ164A

Analyse the operation of HVAC air and hydronic systems

80

UEENEEJ165A

Evaluate thermodynamic and fluid parameters of refrigeration systems

100

UEENEEJ170A

Diagnose and rectify faults in air conditioning and refrigeration control systems

70

UEENEEJ192A

Analyse the psychrometric performance of HVAC/R systems

50

UEENEEJ194A

Solve problems in low voltage refrigeration circuits

40

UEENEEK145A

Implement and monitor energy sector environmental and sustainable energy policies and procedures

20

UEENEEP012A

Disconnect / reconnect composite appliances connected to low voltage installation wiring

60

UEENEEP017A

Locate and rectify faults in low voltage composite appliances using set procedures

20

UEENEEP024A

Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply

20

UEENEEP025A

Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply

20

Total points in core 

1470 

Elective Competency Standard Units 

Complete Elective units to achieve a total of weighting of 130 points from the following groups:

Group 

Minimum points 

Maximum points 

A 

Imported and Common Elective Units 

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 5. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

0

60

B 

Qualification Elective Units 

0

30

C 

Qualification Elective Units 

0

50

D 

Qualification Elective Units 

You may select the majority of your elective units from this Group

50

130

Group A – Imported and Common Electives Units 

You may complete units to a maximum weighting of 60

Weighting Points 

BSBMGT502B

Manage people performance

70

BSBINM501A

Manage an information or knowledge management system

50

BSBMGT516C

Facilitate continuous improvement

60

BSBINN502A

Build and sustain an innovative work environment

50

BSBWOR502B

Ensure team effectiveness

60

CPCCOHS1001A

Work safely in the construction industry

10

HLTCPR211A

Perform CPR

10

MEM16006A

Organise and communicate information

20

MEM16008A

Interact with computing technology

20

MEM30001A

Use computer aided drafting systems to produce basic engineering drawings

40

MEM30002A

Produce basic engineering graphics

40

MEM30003A

Produce detailed engineering drawings

80

MEM30004A

Use CAD to create and display 3D models

40

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 5. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework

Up to 60 points

Group B – Qualification Elective Units 

You may complete units to a maximum weighting of 30

Weighting Points 

UEENEEJ114A

Resolve problems in hydronic systems

40

UEENEEJ115A

Resolve problems in beverage dispensers

40

UEENEEJ116A

Resolve problems in transport refrigeration systems

20

UEENEEJ117A

Resolve problems in ultra-low temperature refrigeration systems

20

UEENEEJ118A

Resolve problems in post mix refrigeration systems

20

UEENEEJ119A

Resolve problems in ice making systems

20

UEENEEJ166A

Resolve problems in dairy refrigeration systems

20

UEENEEJ167A

Resolve problems in central plant air conditioning systems

40

UEENEEJ168A

Maintain microbial control of refrigeration and air conditioning systems

20

UEENEEJ171A

Resolve problems in refrigerated beverage vending cabinets

20

UEENEEJ174A

Apply safety awareness and legal requirements for hydrocarbon refrigerants

10

UEENEEJ175A

Service and repair self contained hydrocarbon air conditioning and refrigeration systems

20

UEENEEJ176A

Install and commission hydrocarbon refrigeration systems, components and associated equipment

20

UEENEEJ178A

Apply safety awareness and legal requirements for ammonia refrigerant

10

UEENEEJ179A

Repair and service ammonia refrigeration systems

20

UEENEEJ180A

Install and commission ammonia refrigeration systems, components and associated equipment

20

UEENEEJ182A

Repair and service secondary refrigeration systems

20

UEENEEJ184A

Apply safety awareness and legal requirements for carbon dioxide refrigerant

10

UEENEEJ185A

Repair and service carbon dioxide refrigeration systems

20

UEENEEJ186A

Install and commission carbon dioxide refrigeration systems, components and associated equipment

20

UEENEEJ188A

Repair and service self contained carbon dioxide refrigeration and heat pump systems

20

Group C – Qualification Elective Units  

You may complete units to a maximum weighting of 50

Weighting Points 

UEENEEC005B

Estimate electrotechnology projects

40

UEENEEE110A

Develop and implement energy sector maintenance programs

60

UEENEEJ128A

Produce HVAC/R system design drawings

80

UEENEEJ130A

Produce HVAC/R control system diagrams

40

UEENEEJ190A

Select basic commercial refrigeration system equipment, components and accessories

40

UEENEEJ191A

Select residential air conditioning system equipment, components, and accessories

40

Group D – Qualification Elective Units  

You must complete units to a minimum weighting of 50

You may select all your elective units from this Group

Weighting Points 

UEENEEC006B

Prepare tender submissions for electrotechnology projects

60

UEENEEE126A

Provide solutions to basic engineering computational problems

60

UEENEEJ131A

Determine noise and vibration encountered in HVAC/R applications

80

UEENEEJ132A

Design commercial refrigeration systems and select components

80

UEENEEJ133A

Design industrial refrigeration systems and select components

80

UEENEEJ134A

Design heating, ventilation and air conditioning (HVAC) systems and select components

60

UEENEEJ135A

Design control systems for refrigeration or heating, ventilation and air conditioning systems

80

UEENEEJ136A

Evaluate and report on building services energy management systems

80

UEENEEJ137A

Evaluate and report on the indoor air quality of buildings

40

UEENEEJ177A

Design hydrocarbon refrigerated systems

40

UEENEEJ181A

Design ammonia refrigerated systems

40

UEENEEJ183A

Design secondary refrigerant systems

40

UEENEEJ187A

Design carbon dioxide refrigerated systems

40

Note:  

1. Pre-requisite pathways shall be identified and met for all elective units selected.

2. In selecting elective units considerations to career planning advice should be given to units that form part of a pre-requisite pathway for the progression to achieve particular competencies or qualification at a higher level.

3. Registered training organisations shall also provide information related to the relevant pathway(s) that may be taken to achieve paraprofessional status ("associate membership") with a professional engineering membership organisation.

END OF QUALIFICATION