Modification History
Release |
Action |
Core/Elective |
Details |
Points |
3 |
Update |
Group A |
HLTCPR211A Perform CPR |
10 |
4 |
Edit |
Group C |
Edit Name to reflect correct Unit title UEENEEI151A Develop, enter and verify word and analogue control programs for programmable logic controllers. |
60 |
5 |
Update |
Elective |
HLTAID001 - Provide cardiopulmonary resuscitation |
10 |
5 |
Edit |
Core |
Correct title of UEENEEJ110A - Select refrigerant piping, accessories and associated controls |
50 |
5 |
Edit |
Core |
Correct title of UEENEEJ153A - Find and rectify faults in motors and associated controls in refrigeration and air conditioning systems |
50 |
5 |
Edit |
Core |
Correct title of UEENEEK145A - Implement and monitor energy sector environmental and sustainable policies and procedures |
20 |
5 |
Edit |
Elective |
Correct title of UEENEEJ178A - Apply safety awareness and legal requirements for ammonia refrigerant |
10 |
Description
Scope
This qualification provides competencies in high level fault diagnosis and rectification, commissioning and maintenance of refrigeration systems and equipment that apply to commercial food storage and preservation, air-conditioning, air distribution equipment and/or special applications. It includes regulatory requirements for purchasing and handling refrigerants.
Note:
The Ozone Protection and Synthetic Greenhouse Gas Legislation Amendment Bill 2003 apply to this qualification. Prior to planning the delivery of any training and/or assessment activities all legislative and regulatory requirements shall be identified and included.
^ From 1 July 2022 the elective unit HLTAID001 must no longer be delivered and will be replaced in the Packaging Rules by the unit HLTAID009 - for more information see: https://asqa.gov.au/news-events/news/reminder-about-superseded-hlt-first-aid-units
Pathways Information
Not Applicable
Licensing/Regulatory Information
Not Applicable
Entry Requirements
Not Applicable
Employability Skills Summary
Not Applicable
Packaging Rules
Completion requirements
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- All the Core competency standard units, defined in the Core Competency Standard Units table below and
- A combination of Elective competency standard units to achieve a total weighting of 180 points in accordance with the Elective Competency Standard Units table below.
Note: UEENEEJ109A - Those holding an ‘Certificate III in Refrigeration and Air-conditioning trade qualification or equivalent" meet the requirements of this unit and its pre-requisite requirements.
Core Competency Standard Units All Core competency standard units to be achieved |
Weighting Points |
|||
UEENEEE038B |
Participate in development and follow a personal competency development plan |
20 |
||
UEENEEE101A |
Apply Occupational Health and Safety regulations, codes and practices in the workplace |
20 |
||
UEENEEE102A |
Fabricate, assemble and dismantle utilities industry components |
40 |
||
UEENEEE103A |
Solve problems in ELV single path circuits |
40 |
||
UEENEEE105A |
Fix and secure electrotechnology equipment |
20 |
||
UEENEEE107A |
Use drawings, diagrams, schedules, standards, codes and specifications |
40 |
||
UEENEEE117A |
Implement and monitor energy sector OHS policies and procedures |
20 |
||
UEENEEE124A |
Compile and produce an energy sector detailed report |
60 |
||
UEENEEE137A |
Document and apply measures to control OHS risks associated with electrotechnology work |
20 |
||
UEENEEJ102A |
Prepare and connect refrigerant tubing and fittings |
30 |
||
UEENEEJ103A |
Establish the basic operating conditions of vapour compression systems |
60 |
||
UEENEEJ104A |
Establish the basic operating conditions of air conditioning systems |
20 |
||
UEENEEJ106A |
Install refrigerant pipe work, flow controls and accessories |
60 |
||
UEENEEJ107A |
Install air conditioning and refrigeration systems, major components and associated equipment |
80 |
||
UEENEEJ108A |
Recover, pressure test, evacuate, charge and leak test refrigerants |
60 |
||
UEENEEJ109A |
Verify functionality and compliance of refrigeration and air conditioning installations |
20 |
||
UEENEEJ110A |
Select refrigerant piping, accessories and associated controls |
50 |
||
UEENEEJ111A |
Diagnose and rectify faults in air conditioning and refrigeration systems and components |
40 |
||
UEENEEJ112A |
Diagnose and rectify faults in complex air conditioning/ refrigeration systems |
100 |
||
UEENEEJ113A |
Commission air conditioning and refrigeration systems |
40 |
||
UEENEEJ153A |
Find and rectify faults in motors and associated controls in refrigeration and air conditioning systems |
50 |
||
UEENEEJ170A |
Diagnose and rectify faults in air conditioning and refrigeration control systems |
70 |
||
UEENEEK145A |
Implement and monitor energy sector environmental and sustainable policies and procedures |
20 |
||
UEENEEP012A |
Disconnect / reconnect composite appliances connected to low voltage installation wiring |
60 |
||
UEENEEP017A |
Locate and rectify faults in low voltage composite appliances using set procedures |
20 |
||
UEENEEP024A |
Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply |
20 |
||
UEENEEP025A |
Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply |
20 |
||
Total points in core |
1100 |
|||
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 180 points from the following groups: |
||||
Groups |
Minimum points |
Maximum points |
||
A |
Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. |
0 |
90 |
|
B |
Qualification Elective Units |
0 |
90 |
|
C |
Qualification Elective Units You may select all your elective units from this Group |
90 |
180 |
Group A – Imported and Common Elective Units You may complete units to a maximum weighting of 90 |
Weighting Points |
|
UEENEEC001B |
Maintain documentation |
20 |
UEENEEC002B |
Source and purchase material/parts for installation or service jobs |
20 |
UEENEEC003B |
Provide quotations for installation or service jobs |
20 |
UEENEEC010B |
Deliver a service to customers |
20 |
UEENEED101A |
Use computer applications relevant to a workplace |
20 |
UEENEEE009B |
Comply with scheduled and preventative maintenance program processes |
20 |
UEENEEE020B |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
CPCCOHS1001A |
Work safely in the construction industry |
10 |
HLTAID001 ^ HLTAID009 |
Provide cardiopulmonary resuscitation Provide cardiopulmonary resuscitation (must be delivered from 1 July 2022) |
10 |
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework |
Up to 90 points |
|
Group B – Qualification Elective Units You may complete units to a maximum weighting of 90 |
Weighting Points |
|
UEENEEI116A |
Assemble, enter and verify operating instructions in microprocessor equipped devices |
20 |
UEENEEI150A |
Develop, enter and verify discrete control programs for programmable controllers |
60 |
UEENEEJ114A |
Resolve problems in hydronic systems |
40 |
UEENEEJ115A |
Resolve problems in beverage dispensers |
40 |
UEENEEJ116A |
Resolve problems in transport refrigeration systems |
20 |
UEENEEJ117A |
Resolve problems in ultra-low temperature refrigeration systems |
20 |
UEENEEJ118A |
Resolve problems in post mix refrigeration systems |
20 |
UEENEEJ119A |
Resolve problems in ice making systems |
20 |
UEENEEJ120A |
Resolve problems in industrial refrigeration systems |
20 |
UEENEEJ167A |
Resolve problems in central plant air conditioning systems |
40 |
UEENEEJ168A |
Maintain microbial control of refrigeration and air conditioning systems |
20 |
UEENEEJ171A |
Resolve problems in refrigerated beverage vending cabinets |
20 |
UEENEEJ174A |
Apply safety awareness and legal requirements for hydrocarbon refrigerants |
10 |
UEENEEJ175A |
Service and repair self contained hydrocarbon air conditioning and refrigeration systems |
20 |
UEENEEJ176A |
Install and commission hydrocarbon refrigeration systems, components and associated equipment |
20 |
UEENEEJ178A |
Apply safety awareness and legal requirements for ammonia refrigerant |
10 |
UEENEEJ179A |
Repair and service ammonia refrigeration systems |
20 |
UEENEEJ180A |
Install and commission ammonia refrigeration systems, components and associated equipment |
20 |
UEENEEJ182A |
Repair and service secondary refrigeration systems |
20 |
UEENEEJ184A |
Apply safety awareness and legal requirements for carbon dioxide refrigerant |
10 |
UEENEEJ185A |
Repair and service carbon dioxide refrigeration systems |
20 |
UEENEEJ186A |
Install and commission carbon dioxide refrigeration systems, components and associated equipment |
20 |
UEENEEJ188A |
Repair and service self contained carbon dioxide refrigeration and heat pump systems |
20 |
Group C – Qualification Elective Units You must complete units to a minimum weighting of 90 You may select all your elective units from this Group |
Weighting Points |
|
UEENEEE110A |
Develop and implement energy sector maintenance programs |
60 |
UEENEEI151A |
Develop, enter and verify word and analogue control programs for programmable logic controllers. |
60 |
UEENEEI152A |
Develop, enter and verify programs in Supervisory Control and Data Acquisition systems |
60 |
UEENEEJ121A |
Monitor and adjust refrigeration energy management systems |
40 |
UEENEEJ122A |
Diagnose faults in complex HVAC /refrigeration control systems |
80 |
UEENEEJ123A |
Commission complex (HVAC) heating, ventilation and air conditioning systems |
80 |
UEENEEJ124A |
Commission refrigeration/air conditioning hydronic systems |
80 |
UEENEEJ125A |
Commission complex refrigeration systems and equipment |
80 |
UEENEEJ126A |
Commission complex refrigeration/air conditioning control systems |
40 |
Note:
1. Pre-requisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a pre-requisite pathway for the progression to achieve particular competencies or qualification at a higher level.
END OF QUALIFICATION