Qualification details

UEE42622 - Certificate IV in Hazardous areas - Electrical (Release 1)

Summary

Usage recommendation:
Current
Mapping:
MappingNotesDate
Supersedes UEE42620 - Certificate IV in Hazardous areas - Electrical 23/Oct/2022

Release Status:
Current
Releases:
ReleaseRelease date
1 1 (this release) 24/Oct/2022


Units of competency

CodeSort Table listing Units of Competency by the Code columnTitleSort Table listing Units of Competency by the Title columnUsage RecommendationSort Table listing Units of Competency by the Usage Recommendation columnEssentialSort Table listing Units of Competency by the Essential column
UEEHA0020 - Conduct detailed inspection of electrical installations for hazardous areasConduct detailed inspection of electrical installations for hazardous areasCurrentElective
UEEHA0033 - Supervise repair and overhaul of explosion-protected equipment type intrinsically safe (Ex i)Supervise repair and overhaul of explosion-protected equipment type intrinsically safe (Ex i)CurrentElective
UEEHA0035 - Supervise repair and overhaul of explosion-protected rotating machinesSupervise repair and overhaul of explosion-protected rotating machinesCurrentElective
UEECO0017 - Source and purchase material/parts for installation or service jobsSource and purchase material/parts for installation or service jobsCurrentElective
UEEHA0024 - Inspect, maintain and fit plugs/couplers for reeling, trailing and flexible cables - coal miningInspect, maintain and fit plugs/couplers for reeling, trailing and flexible cables - coal miningCurrentElective
UEEHA0025 - Install explosion-protected equipment and associated apparatus and wiring systemsInstall explosion-protected equipment and associated apparatus and wiring systemsCurrentElective
UEEHA0030 - Repair reeling, trailing and flexible cables used in coal miningRepair reeling, trailing and flexible cables used in coal miningCurrentElective
UEEHA0029 - Plan electrical installations for hazardous areasPlan electrical installations for hazardous areasCurrentElective
ICTICT214 - Operate application software packagesOperate application software packagesCurrentElective
UEEHA0026 - Maintain equipment associated with hazardous areasMaintain equipment associated with hazardous areasCurrentElective
Items per page 10 | 20 | 50 | 100
Displaying items 1 - 10 of 31

Classifications

SchemeCodeClassification value
ANZSCO Identifier 341111 Electrician (General) 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 
Qualification/Course Level of Education Identifier 511 Certificate IV 
Taxonomy - Industry Sector N/A Electrotechnology 
Taxonomy - Occupation N/A Electrician (Hazardous Areas) 

Classification history

SchemeCodeClassification valueStart dateEnd date
ANZSCO Identifier 341111 Electrician (General) 20/Dec/2022 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 20/Dec/2022 
Qualification/Course Level of Education Identifier 511 Certificate IV 24/Oct/2022 
The content being displayed has been produced by a third party, while all attempts have been made to make this content as accessible as possible it cannot be guaranteed. If you are encountering issues following the content on this page please consider downloading the content in its original form

Modification History

Release 1. This is the first release of this qualification in the UEE Electrotechnology Training Package.

This qualification replaces and is not equivalent to UEE42620 Certificate IV in Hazardous areas - Electrical.

Modifications in this release include:

  • UEEHA0025 and UEEHA0026 removed from group B (they are in Group C).
  • UEEHA0037, UEEHA0024, UEEHA0036 and UEEHA0030 added to group B.
  • UEEHA0027 added to Group C.
  • Codes of superseded units updated.

Qualification Description

This qualification provides competencies to supervise selection, installation, commissioning maintenance and testing of explosion-protected equipment and systems for control and monitoring of plant and processes.

The qualification provides competencies in working with explosion-protection techniques.

It includes requirements and competencies to select, install, set up, test, fault find, repair and maintain stand-alone renewable energy equipment and systems.

No licensing, legislative or certification requirements apply to this qualification at the time of publication.

Entry Requirements

The entry requirement for this qualification is:

  • Certificate III in Electrotechnology Electrician

or

  • a current ‘Unrestricted Electricians Licence’ or its equivalent issued in an Australian state or territory.

Packaging Rules

A total of 440 weighting points  comprising:

200 core weighting points  listed below; plus 

240 general elective weighting points  from the general elective units listed below.

Choose a total of 240 weighting points  elective units from the list below, of which between 0 and 60 weighting points  can be taken from Group A; between 0 and 80 weighting points  can be taken from Group B; and between 140 and 240 can be taken from Group C (or all 240 elective weighting points  can be taken from Group C).

Up to 60 weighting points of the general elective units Group A , may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC).

There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume.

Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with.

Core units  

Weighting Points 

UEECD0010

Compile and produce an energy sector detailed report

60

UEECD0024

Implement and monitor energy sector WHS policies and procedures

20

UEECD0027

Participate in development and follow a personal competency development plan

20

UEEHA0004

Enter a classified hazardous area to undertake work related to electrical equipment

40

UEEHA0022

Determine the explosion-protection requirements to meet a specified classified hazardous area*

40

UEERE0015

Implement and monitor energy sector environmental and sustainable policies and procedures

20

Group A: Imported and common elective units 

Weighting Points 

BSBOPS203

Deliver a service to customers

20

ICTICT214

Operate application software packages

20

UEECD0011

Comply with scheduled and preventative maintenance program processes

20

UEECD0035

Provide basic instruction in the use of electrotechnology apparatus

20

UEECO0002

Maintain documentation

20

UEECO0015

Provide quotations for installation or service jobs

20

UEECO0017

Source and purchase material/parts for installation or service jobs

20

Group B: General elective units 

Weighting Points 

UEECD0050

Use and maintain the integrity of a portable gas detection device*

20

UEEHA0024

Inspect, maintain and fit plugs/couplers for reeling, trailing and flexible cables - coal mining*

60

UEEHA0030

Repair reeling, trailing and flexible cables used in coal mining

60

UEEHA0031

Supervise repair and overhaul of explosion-protected equipment type flameproof (Ex d)*

60

UEEHA0032

Supervise repair and overhaul of explosion-protected equipment type increased safety (Ex e)*

60

UEEHA0033

Supervise repair and overhaul of explosion-protected equipment type intrinsically safe (Ex i)*

60

UEEHA0034

Supervise repair and overhaul of explosion-protected equipment type pressurised (Ex p)*

60

UEEHA0035

Supervise repair and overhaul of explosion-protected rotating machines*

60

UEEHA0036

Test reeling, trailing and flexible cables and their attachments used in coal mining*

60

UEEHA0037

Verify compliance of repaired reeling, trailing and flexible cables and attachments - coal mining*

60

UEEHA0039

Supervise repair and overhaul of explosion-protected equipment type Group III (‘t’)*

60

Group C: General elective units 

Weighting Points 

UEEHA0020

Conduct detailed inspection of electrical installations for hazardous areas*

40

UEEHA0023

Develop and manage periodic electrical inspection and maintenance programs for hazardous areas*

20

UEEHA0025

Install explosion-protected equipment and associated apparatus and wiring systems*

60

UEEHA0026

Maintain equipment associated with hazardous areas*

60

UEEHA0027

Manage continuous supervision inspection of electrical installations for hazardous areas*

40

UEEHA0029

Plan electrical installations for hazardous areas*

20

UEEHA0038

Conduct visual and close inspection of electrical installations for hazardous areas*

40

Qualification Mapping Information

This qualification replaces and is not equivalent to UEE42620 Certificate IV in Hazardous areas - Electrical.

Links

Companion Volume Implementation Guides are found in VETNet - https://vetnet.gov.au/Pages/TrainingDocs.aspx?q=b8a8f136-5421-4ce1-92e0-2b50341431b6