Modification History
Release 3. Updated superseded elective units. |
Release 2: Two units added to Group B General Electives. Imported elective units updated. |
Release 1. This is the first release of this qualification in the UEE Electrotechnology Training Package |
Qualification Description
This qualification provides competencies to set up and manage an electrical contracting business. It includes competencies required by regulations for an electrical contracting licence; and requirements and competencies to select, install, set up, test, fault find, repair and maintain photovoltaic systems and associated equipment. No licensing, legislative or certification requirements apply to this qualification at the time of publication. |
Entry Requirements
The entry requirement for this qualification is:
or
|
Packaging Rules
A total of 360 weighting points comprising: 120 core weighting points listed below; plus 240 general elective weighting points from the general elective units listed below. Choose a total of 240 weighting points elective units from the list below, of which between 0 and 120 weighting points can be taken from Group A; between 0 and 120 weighting points can be taken from Group B; and between 120 and 240 can be taken from Group C (or all 240 elective weighting points can be taken from Group C). Up to 120 weighting points of the general elective units Group A , may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC). There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume. Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with. |
||
Core units |
Weighting Points |
|
UEECD0010 |
Compile and produce an energy sector detailed report |
60 |
UEECD0024 |
Implement and monitor energy sector WHS policies and procedures |
20 |
UEECD0027 |
Participate in development and follow a personal competency development plan |
20 |
UEERE0015 |
Implement and monitor energy sector environmental and sustainable policies and procedures |
20 |
Group A: Imported and common elective units |
Weighting Points |
|
BSBOPS203 |
Deliver a service to customers |
20 |
CPCWHS1001 |
Prepare to work safely in the construction industry |
10 |
HLTAID009 |
Provide cardiopulmonary resuscitation |
10 |
ICTICT214 |
Operate application software packages |
20 |
UEECD0011 |
Comply with scheduled and preventative maintenance program processes |
20 |
UEECD0035 |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
UEECO0002 |
Maintain documentation |
20 |
UEECO0015 |
Provide quotations for installation or service jobs |
20 |
UEECO0017 |
Source and purchase material/parts for installation or service jobs |
20 |
Group B: General elective units |
Weighting Points |
|
UEECD0030 |
Prepare electrotechnology/utilities drawings using manual drafting and CAD equipment and software* |
60 |
UEECD0031 |
Prepare engineering drawings using manual drafting and CAD for electrotechnology applications* |
60 |
UEECS0033 |
Use engineering applications software on personal computers |
40 |
UEEEL0078 |
Install and commission whole current electricity meters* |
20 |
UEEEL0016 |
Provide advice on effective and energy efficient lighting products |
20 |
UEEEL0022 |
Supply effective and efficient lighting products for domestic and small commercial applications* |
40 |
UEEEL0049 |
Install and maintain emergency safety systems* |
60 |
UEEEL0061 |
Provide advice on the application of energy efficient lighting for ambient and aesthetic effect* |
20 |
UEEEL0069 |
Select and arrange equipment for special LV electrical installations* |
60 |
UEEEL0076 |
Inspect, test and maintain emergency lighting systems* |
20 |
UEEEL0075 |
Inspect, test and maintain emergency alarm systems and equipment* |
20 |
Group C: General elective units |
Weighting Points |
|
UEECD0032 |
Produce detailed electrotechnology/utilities drawings using CAD equipment and software* |
60 |
UEECO0001 |
Estimate electrotechnology projects |
40 |
UEECO0013 |
Prepare specifications for the supply of materials and equipment for electrotechnology projects |
40 |
UEECO0025 |
Provide quotations for inspection and compliance audit services |
20 |
UEEEL0007 |
Develop detailed electrical drawings* |
60 |
UEEEL0027 |
Carry out low voltage electrical field testing and report findings* |
60 |
UEEEL0029 |
Conduct compliance inspection of LV electrical installations with demand exceeding 100 A per phase* |
40 |
UEEEL0030 |
Conduct compliance inspection of single phase LV electrical installations* |
60 |
UEEEL0031 |
Conduct compliance inspection of special LV electrical installations* |
60 |
UEEEL0036 |
Design effective and efficient lighting for residential and commercial buildings* |
20 |
UEEEL0040 |
Develop compliance policies and plans to conduct an electrical contracting business* |
80 |
UEEEL0050 |
Install and replace low voltage current transformer metering* |
20 |
UEEEL0051 |
Investigate and report on electrical incidents and causes* |
60 |
UEEEL0057 |
Plan electrical installations with a low voltage demand up to 400 A per phase* |
40 |
UEEEL0059 |
Plan low voltage switchboard and control panel layouts* |
40 |
UEEEL0060 |
Prepare quotations for the supply of effective and efficient lighting products for lighting projects* |
20 |
UEEEL0063 |
Provide photometric data for illumination system design |
60 |
UEEEL0070 |
Select effective and efficient light sources and luminaries for given locations and designs* |
60 |
UEEEL0071 |
Select low voltage power factor correction equipment* |
40 |
UEEEL0072 |
Set up and place LV electrical apparatus and associated circuits into service* |
40 |
UEEEL0073 |
Verify compliance and functionality of special LV electrical installations* |
40 |
Qualification Mapping Information
This qualification replaces and is not equivalent to UEE42111 Certificate IV in Electrotechnology – Electrical Contracting |
Links
Companion Volume Implementation Guides are found in VETNet - https://vetnet.gov.au/Pages/TrainingDocs.aspx?q=b8a8f136-5421-4ce1-92e0-2b50341431b6