Modification History
Release 2. Updated superseded HLT, BSB and ICT elective units. Release 1. This is the first release of this qualification in the UEE Electrotechnology Training Package |
Qualification Description
This qualification provides competencies to install, certify, fault find and maintain rail signalling equipment and systems. This includes requirements for performing like-for-like replacement, performing authorised installations and alterations, and applying emergency operational restriction. It excludes changing circuit principles, changing the design function and commissioning. No licensing, legislative or certification requirements apply to this qualification at the time of publication. |
Entry Requirements
The entry requirement for this qualification is:
or
|
Packaging Rules
A total of 510 weighting points comprising: 440 core weighting points listed below; plus 70 general elective weighting points from the general elective units listed below. Choose a total of 70 weighting points elective units from the list below, of which between 0 and 30 weighting points can be taken from Group A; of which between 0 and 40 weighting points can be taken from Group B; and between 30 and 70 weighting points can be taken from Group C (or all 70 elective weighting points can be taken from Group C). Up to 30 weighting points of the general elective units Group A , may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC). There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume. Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with. |
||
Core units |
Weighting Points |
|
UEECD0024 |
Implement and monitor energy sector WHS policies and procedures |
20 |
UEECD0027 |
Participate in development and follow a personal competency development plan |
20 |
UEERE0015 |
Implement and monitor energy sector environmental and sustainable policies and procedures |
20 |
UEERS0001 |
Assemble and wire internal electrical rail signalling equipment* |
30 |
UEERS0004 |
Find and repair rail signalling system faults* |
20 |
UEERS0005 |
Install and maintain active level crossing equipment* |
40 |
UEERS0009 |
Install and maintain power-operated point actuating devices* |
40 |
UEERS0010 |
Install and maintain rail signalling power supplies* |
40 |
UEERS0011 |
Install and maintain rail track circuit leads and bonds* |
30 |
UEERS0012 |
Install and maintain trackside signal and train protection equipment* |
40 |
UEERS0013 |
Install and maintain train detection equipment* |
40 |
UEERS0014 |
Install and maintain vital relay interlocking systems* |
40 |
UEERS0017 |
Repair rail signalling power and control cables* |
40 |
UEERS0019 |
Test copper rail signalling cables* |
20 |
Group A: Imported and common elective units |
Weighting Points |
|
BSBOPS203 |
Deliver a service to customers |
20 |
CPCCWHS1001 |
Prepare to work safely in the construction industry |
10 |
HLTAID009 |
Provide cardiopulmonary resuscitation |
10 |
ICTICT214 |
Operate application software packages |
20 |
TLIS2004 |
Install and maintain rail bonding systems |
40 |
UEECD0011 |
Comply with scheduled and preventative maintenance program processes |
20 |
UEECD0035 |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
UEECO0002 |
Maintain documentation |
20 |
UEECO0015 |
Provide quotations for installation or service jobs |
20 |
UEECO0017 |
Source and purchase material/parts for installation or service jobs |
20 |
Group B: General elective units |
Weighting Points |
|
UEECS0029 |
Set up and configure basic local area network (LAN)* |
80 |
UEECS0033 |
Use engineering applications software on personal computers |
40 |
Group C: General elective units |
Weighting Points |
|
UEECD0010 |
Compile and produce an energy sector detailed report |
60 |
UEECD0058 |
Observe safety practices are followed in the vicinity of isolated electrical cables* |
20 |
UEERS0002 |
Decommission electrical and electromechanical rail signalling from service* |
20 |
UEERS0003 |
Develop rail signalling system maintenance programs* |
20 |
UEERS0006 |
Install and maintain computer-based interlocking rail systems* |
30 |
UEERS0007 |
Install and maintain non-vital screen-based control systems* |
20 |
UEERS0008 |
Install and maintain non-vital telemetry systems* |
40 |
UEERS0015 |
Maintain electronic and microprocessor-based remote control systems* |
20 |
UEERS0016 |
Maintain mechanical rail signalling equipment and infrastructure* |
20 |
UEERS0018 |
Test and commission rail power equipment* |
20 |
Qualification Mapping Information
This qualification replaces and is not equivalent to UEE41211 Certificate IV in Electrical – Rail Signalling |
Links