Modification History
Release 1. This is the first release of this qualification in the UEE Electrotechnology Training Package |
Qualification Description
This qualification covers competencies to develop strategies for the reduction of energy in buildings and to recommend changes in the way in which energy is controlled in the building, either by the installation of new control equipment or by the modification or re-programming of existing control equipment. No licensing, legislative or certification requirements apply to this qualification at the time of publication. |
Entry Requirements
The entry requirement for this qualification is:
or
|
Packaging Rules
A total of 440 weighting points comprising: 140 core weighting points listed below; plus 300 general elective weighting points from the general elective units listed below. Choose a total of 300 weighting points elective units from the list below, of which between 0 and 100 weighting points can be taken from Group A; between 0 and 100 weighting points can be taken from Group B; and between 200 and 300 weighting points can be taken from Group C (or all electives units of 300 weighting points can be taken from Group C). Up to 100 weighting points of the general elective units Group A , may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided that selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC). There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume. Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with. |
||
Core units |
Weighting Points |
|
UEECD0010 |
Compile and produce an energy sector detailed report |
60 |
UEECD0024 |
Implement and monitor energy sector WHS policies and procedures |
20 |
UEECD0027 |
Participate in development and follow a personal competency development plan |
20 |
UEERE0014 |
Develop strategies to address sustainability issues for electrical installations* |
20 |
UEERE0015 |
Implement and monitor energy sector environmental and sustainable policies and procedures |
20 |
Group A: Imported and common elective units |
Weighting Points |
|
BSBCUS201 |
Deliver a service to customers |
20 |
CPCCWHS1001 |
Prepare to work safely in the construction industry |
10 |
HLTAID001 |
Provide cardiopulmonary resuscitation |
10 |
ICTICT203 |
Operate application software packages |
20 |
UEECD0011 |
Comply with scheduled and preventative maintenance program processes |
20 |
UEECD0035 |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
UEECO0002 |
Maintain documentation |
20 |
UEECO0015 |
Provide quotations for installation or service jobs |
20 |
UEECO0017 |
Source and purchase material/parts for installation or service jobs |
20 |
Group B: Qualification elective units |
Weighting Points |
|
UEECD0028 |
Plan an integrated cabling installation system* |
40 |
UEECS0033 |
Use engineering applications software on personal computers |
40 |
UEEDV0005 |
Install and maintain cabling for multiple access to telecommunication services* |
80 |
UEEDV0008 |
Install, modify and verify coaxial and structured communication copper cabling* |
40 |
UEEEC0060 |
Repairs basic electronic apparatus faults by replacement of components* |
40 |
UEEEC0075 |
Troubleshoot single phase input d.c power supplies* |
40 |
UEEEL0013 |
Install, set up and commission interval metering* |
20 |
UEEEL0016 |
Provide advice on effective and energy efficient lighting products |
20 |
UEEEL0022 |
Supply effective and efficient lighting products for domestic and small commercial applications* |
40 |
UEEEL0048 |
Install and maintain emergency lighting systems* |
40 |
UEEEL0049 |
Install and maintain emergency safety systems* |
60 |
UEEEL0061 |
Provide advice on the application of energy efficient lighting for ambient and aesthetic effect* |
20 |
UEEIC0002 |
Assemble, enter and verify operating instructions in microprocessor equipped devices* |
20 |
UEEIC0011 |
Develop electrical integrated systems* |
20 |
UEEIC0013 |
Develop, enter and verify discrete control programs for programmable controllers* |
60 |
UEEIC0038 |
Solve problems in density/level measurement components and systems* |
40 |
UEEIC0039 |
Solve problems in flow measurement components and systems* |
40 |
UEEIC0041 |
Solve problems in pressure measurement components and systems* |
40 |
UEEIC0043 |
Solve problems in temperature measurement components and systems* |
40 |
Group C: Qualification elective units |
Weighting Points |
|
UEECD0061 |
Write specifications for refrigeration and air conditioning engineering projects |
40 |
UEEEL0007 |
Develop detailed electrical drawings* |
60 |
UEEEL0029 |
Conduct compliance inspection of LV electrical installations with demand exceeding 100 A per phase* |
40 |
UEEEL0030 |
Conduct compliance inspection of single phase LV electrical installations* |
60 |
UEEEL0031 |
Conduct compliance inspection of special LV electrical installations* |
60 |
UEEEL0036 |
Design effective and efficient lighting for residential and commercial buildings* |
20 |
UEEEL0040 |
Develop compliance policies and plans to conduct an electrical contracting business* |
80 |
UEEEL0044 |
Diagnose and rectify faults in complex lift systems* |
40 |
UEEEL0050 |
Install and replace low voltage current transformer metering* |
20 |
UEEEL0051 |
Investigate and report on electrical incidents and causes* |
60 |
UEEEL0057 |
Plan electrical installations with a low voltage demand up to 400 A per phase* |
40 |
UEEEL0059 |
Plan low voltage switchboard and control panel layouts* |
40 |
UEEEL0060 |
Prepare quotations for the supply of effective and efficient lighting products for lighting projects* |
20 |
UEEEL0063 |
Provide photometric data for illumination system design |
60 |
UEEEL0070 |
Select effective and efficient light sources and luminaries for given locations and designs* |
60 |
UEEEL0071 |
Select low voltage power factor correction equipment* |
40 |
UEEEL0072 |
Set up and place LV electrical apparatus and associated circuits into service* |
40 |
UEEEL0073 |
Verify compliance and functionality of special LV electrical installations* |
40 |
UEERE0003 |
Assess energy loads and uses for energy efficiency in commercial facilities* |
40 |
UEERE0004 |
Assess energy loads and uses for energy efficiency in industrial properties and enterprises* |
40 |
UEERE0005 |
Assess energy loads and uses for energy efficiency in residential, office and retail premises* |
40 |
Qualification Mapping Information
This qualification replaces and is not equivalent to UEE41011 Certificate IV in Energy Management and Control |
Links
Companion Volume implementation guides are found in VETNet - - https://vetnet.gov.au/Pages/TrainingDocs.aspx?q=b8a8f136-5421-4ce1-92e0-2b50341431b6