Qualification details

UEE40811 - Certificate IV in Electrical - Fire Protection Control Systems (Release 4)

Summary

Usage recommendation:
Superseded
Mapping:
MappingNotesDate
Supersedes and is equivalent to UEE40810 - Certificate IV in Electrical - Fire Protection Control Systems 15/Mar/2012
Is superseded by and equivalent to UEE40820 - Certificate IV in Electrical - Fire Protection Control Systems 04/Oct/2020

Releases:
ReleaseRelease date
4 (this release) 17/Apr/2014
(View details for release 3) 14/Aug/2013
(View details for release 2) 06/Mar/2013
(View details for release 1) 16/Mar/2012

Units of competency

CodeSort Table listing Units of Competency by the Code columnTitleSort Table listing Units of Competency by the Title columnUsage RecommendationSort Table listing Units of Competency by the Usage Recommendation columnEssentialSort Table listing Units of Competency by the Essential column
UEENEEC003B - Provide quotations for installation or service jobsProvide quotations for installation or service jobsSupersededElective
UEENEEH161A - Install fire detection and warning system apparatusInstall fire detection and warning system apparatusSupersededCore
UEENEED101A - Use computer applications relevant to a workplaceUse computer applications relevant to a workplaceDeletedElective
HLTAID001 - Provide cardiopulmonary resuscitationProvide cardiopulmonary resuscitationSupersededElective
UEENEEG121A - Verify compliance and functionality of special LV electrical installationsVerify compliance and functionality of special LV electrical installationsSupersededElective
UEENEEG108A - Trouble-shoot and repair faults in low voltage electrical apparatus and circuitsTrouble-shoot and repair faults in low voltage electrical apparatus and circuitsDeletedCore
UEENEEE124A - Compile and produce an energy sector detailed reportCompile and produce an energy sector detailed reportSupersededCore
UEENEEG109A - Develop and connect electrical control circuitsDevelop and connect electrical control circuitsSupersededCore
UEENEEE038B - Participate in development and follow a personal competency development planParticipate in development and follow a personal competency development planSupersededCore
UEENEEG102A - Solve problems in low voltage a.c. circuitsSolve problems in low voltage a.c. circuitsSupersededCore
Items per page 10 | 20 | 50 | 100
Displaying items 1 - 10 of 60

Classifications

SchemeCodeClassification value
ANZSCO Identifier 342315 Electronic Instrument Trades Worker (Special Class) 
ASCO (occupation type) Identifier 4311-11 General Electrician 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 
Qualification/Course Level of Education Identifier 511 Certificate IV 
Taxonomy - Industry Sector N/A Electrotechnology,Fire Protection,Electrical Engineering,Fire and Security 
Taxonomy - Occupation N/A Electrician (Special Class),Fire Protection Control Systems Technician,Fire Protection Technician,Fire Safety Systems Inspector 

Classification history

SchemeCodeClassification valueStart dateEnd date
ANZSCO Identifier 342315 Electronic Instrument Trades Worker (Special Class) 07/Aug/2012 
ASCO (occupation type) Identifier 4311-11 General Electrician 07/Aug/2012 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 07/Aug/2012 
Qualification/Course Level of Education Identifier 511 Certificate IV 16/Mar/2012 
The content being displayed has been produced by a third party, while all attempts have been made to make this content as accessible as possible it cannot be guaranteed. If you are encountering issues following the content on this page please consider downloading the content in its original form

Modification History

Release

Action

Core/Elective

Details

Points

2

Edit

Edit Name to reflect correct Unit title

UEENEED104A Use engineering applications software on personal computers

40

2

Update

Group A

HLTCPR211A Perform CPR

10

2

Update

Group A

CPPFES2043A Prevent ozone depleting substance and synthetic greenhouse gas emissions

10

3

Edit

Group C

Edit Name to reflect correct Unit title

UEENEEI151A Develop, enter and verify word and analogue control programs for programmable logic controllers.

60

3

Edit

Core

Edit Name to reflect correct Unit title

UEENEEK145A Implement and monitor energy sector environmental and sustainable policies and procedures

20

4

Update

Elective

HLTAID001 - Provide cardiopulmonary resuscitation

10

4

Edit

Core

Correct title of UEENEEE101A - Apply Occupational Health and Safety regulations, codes and practices in the workplace

20

4

Edit

Core

Correct title of UEENEEE102A - Fabricate, assemble and dismantle utilities industry components

40

4

Edit

Core

Correct title of UEENEEH161A - Install fire detection and warning system apparatus

40

4

Edit

Core

Correct title of UEENEEH162A - Verify compliance and functionality of fire protection system installations

60

4

Edit

Core

Correct title of UEENEEH163A - Enter and verify programs for fire protection systems

40

4

Edit

Core

Correct title of UEENEEH164A - Commission large fire protection systems

40

4

Edit

Core

Correct title of UEENEEH165A - Troubleshoot fire protection systems

40

4

Edit

Elective

Correct title of UEENEED101A - Use computer applications relevant to a workplace

20

4

Edit

Elective

Correct title of UEENEEG113A - Install and maintain emergency safety systems

60

4

Edit

Elective

Correct title of UEENEEG172A - Investigate and report on electrical incidents and causes

60

4

Edit

Elective

Correct title of UEENEEH102A - Repairs basic electronic apparatus faults by replacement of components

40

4

Edit

Elective

Correct title of UEENEEI116A - Assemble, enter and verify operating instructions in microprocessor equipped devices

20

4

Edit

Elective

Correct title of UEENEEI151A - Develop, enter and verify word and analogue control programs for programmable logic controllers.

60

4

Edit

Elective

Correct title of UEENEEM024A - Install explosion-protected equipment and wiring systems - gas atmospheres

40

Description

Scope 

This qualification provides competencies to select, install, commission, fault find and maintain fire protection control systems in buildings. It includes ERAC requirements for an ‘Electrician’s licence’.

Pathways Information

Not applicable.

Licensing/Regulatory Information

Not applicable.

Entry Requirements

Not applicable.

Employability Skills Summary

Not applicable.

Packaging Rules

Completion requirements 

The requirements for granting this qualification will be met when competency is demonstrated and achieved for:

  • All the Core competency standard units, defined in the Core Competency Standard Units table below and
  • A combination of Elective competency standard units to achieve a total weighting of 100 points in accordance with the Elective Competency Standard Units table below.

Note: UEENEEG105A - Those holding an ‘Unrestricted Electricians Licence or equivalent issued in an Australian State or Territory meets the requirements of this unit and its pre-requisite requirements.

Core Competency Standard Units  

All Core competency standard units to be achieved

Weighting Points 

UEENEEE038B

Participate in development and follow a personal competency development plan

20

UEENEEE101A

Apply Occupational Health and Safety regulations, codes and practices in the workplace

20

UEENEEE102A

Fabricate, assemble and dismantle utilities industry components

40

UEENEEE104A

Solve problems in d.c. circuits

80

UEENEEE105A

Fix and secure electrotechnology equipment

20

UEENEEE107A

Use drawings, diagrams, schedules, standards, codes and specifications

40

UEENEEE117A

Implement and monitor energy sector OHS policies and procedures

20

UEENEEE124A

Compile and produce an energy sector detailed report

60

UEENEEE137A

Document and apply measures to control OHS risks associated with electrotechnology work

20

UEENEEG006A

Solve problems in single and three phase low voltage machines

80

UEENEEG033A

Solve problems in single and three phase low voltage electrical apparatus and circuits

60

UEENEEG063A

Arrange circuits, control and protection for general electrical installations

40

UEENEEG101A

Solve problems in electromagnetic devices and related circuits

60

UEENEEG102A

Solve problems in low voltage a.c. circuits

80

UEENEEG103A

Install low voltage wiring and accessories

20

UEENEEG104A

Install appliances, switchgear and associated accessories for low voltage electrical installations

20

UEENEEG105A

Verify compliance and functionality of low voltage general electrical installations

40

UEENEEG106A

Terminate cables, cords and accessories for low voltage circuits

40

UEENEEG107A

Select wiring systems and cables for low voltage general electrical installations

60

UEENEEG108A

Trouble-shoot and repair faults in low voltage electrical apparatus and circuits

40

UEENEEG109A

Develop and connect electrical control circuits

80

UEENEEH161A

Install fire detection and warning system apparatus

40

UEENEEH162A

Verify compliance and functionality of fire protection system installations

60

UEENEEH163A

Enter and verify programs for fire protection systems

40

UEENEEH164A

Commission large fire protection systems

40

UEENEEH165A

Troubleshoot fire protection systems

40

UEENEEK145A

Implement and monitor energy sector environmental and sustainable policies and procedures

20

Total points in core 

1180 

Elective Competency Standard Units 

Complete Elective units to achieve a total of weighting of 100 points from the following groups:

Group 

Minimum points 

Maximum points 

A 

Imported and Common Elective Units 

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

0

60

B 

Qualification Elective Units  

0

60

C 

Qualification Elective Units  

You may select all your elective units from this Group

40

100

Group A – Imported and Common Elective Units 

You may complete units to a maximum weighting of 60

Weighting Points 

UEENEEC001B

Maintain documentation

20

UEENEEC002B

Source and purchase material/parts for installation or service jobs

20

UEENEEC003B

Provide quotations for installation or service jobs

20

UEENEEC010B

Deliver a service to customers

20

UEENEED101A

Use computer applications relevant to a workplace

20

UEENEEE009B

Comply with scheduled and preventative maintenance program processes

20

UEENEEE020B

Provide basic instruction in the use of electrotechnology apparatus

20

CPCCOHS1001A

Work safely in the construction industry

10

HLTAID001

Provide cardiopulmonary resuscitation

10

CPPFES2043A

Prevent ozone depleting substance and synthetic greenhouse gas emissions

10

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework

Up to 60 points

Group B – Qualification Elective Units 

You may complete units to a maximum weighting of 60

Weighting Points 

UEENEED104A

Use engineering applications software on personal computers

40

UEENEEF102A

Install and maintain cabling for multiple access to telecommunication services

120

UEENEEF104A

Install and modify performance data communication copper cabling

40

UEENEEF105A

Install and modify optical fibre performance data communication cabling

40

UEENEEG113A

Install and maintain emergency safety systems

60

UEENEEH102A

Repairs basic electronic apparatus faults by replacement of components

40

UEENEEH111A

Troubleshoot single phase input d.c. power supplies

40

UEENEEH138A

Fault find and repair complex power supplies

40

UEENEEI116A

Assemble, enter and verify operating instructions in microprocessor equipped devices

20

UEENEEI150A

Develop, enter and verify discrete control programs for programmable controllers

60

UEENEEM024A

Install explosion-protected equipment and wiring systems — gas atmospheres

60

UEENEEM077A

Install and maintain the integrity of fixed gas detection equipment

20

UEENEEM080A

Report on the integrity of explosion-protected equipment in a hazardous area

20

Group C – Qualification Elective Units 

You must complete units to a minimum weighting of 40

You may select all your elective units from this Group

Weighting Points 

UEENEEG121A

Verify compliance and functionality of special LV electrical installations

40

UEENEEG122A

Conduct compliance inspection of single phase LV electrical installations

60

UEENEEG123A

Conduct compliance inspection of LV electrical installations with demand exceeding 100 A per phase

40

UEENEEG124A

Conduct compliance inspection of special LV electrical installations

60

UEENEEG172A

Investigate and report on electrical incidents and causes

60

UEENEEG175A

Develop compliance policies and plans to conduct a electrical contracting business

80

UEENEEG179A

Develop detailed electrical drawings

60

UEENEEI151A

Develop, enter and verify word and analogue control programs for programmable logic controllers.

60

UEENEEI152A

Develop, enter and verify programs in Supervisory Control and Data Acquisition systems

60

UEENEEM042A

Install explosion-protected equipment and wiring systems - gas atmospheres

40

Note:  
1. Prerequisite pathways shall be identified and met for all elective units selected.

2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.

END OF QUALIFICATION 

Custom Content Section