Modification History
Release 3. Updated superseded imported elective units. |
Release 2: This minor update is the second release of this qualification in the UEE Electrotechnology Training Package. An incorrect reference to the Refrigeration handling licence entry requirement was fixed. Imported elective units updated. |
Release 1. This is the first release of this qualification in the UEE Electrotechnology Training Package |
Qualification Description
This qualification covers competencies to select, install, commission, fault find and maintain electrical systems and equipment in buildings and premises and split air conditioning systems to a prescribed routine where the maximum plant capacity for each system does not exceed 18 kilowatt (kW). It includes regulatory requirements for purchasing and handling refrigerants for split systems. Split systems include wall hung, floor and ceiling suspended, cassette and ducted fan coil split systems. This qualification excludes competencies required for service, repair, maintenance or the safe and proper installation of commercial refrigeration and air conditioning plant and equipment No licensing, legislative or certification requirements apply to this qualification at the time of publication. |
Entry Requirements
The entry requirement for this qualification is:
or
and
|
Packaging Rules
A total of 450 weighting points comprising: 290 core weighting points listed below; plus 160 general elective weighting points from the general elective units listed below. Choose a total of 160 weighting points elective units from the list below, of which between 0 and 80 weighting points can be taken from Group A; and between 0 and 80 weighting points can be taken from Group B; and between 80 and 160 weighting points can be taken from Group C (or all electives units of 160 weighting points can be taken from Group C). Up to 80 weighting points of the general elective units Group A, may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC). There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume. Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with. |
||
Core units |
Weighting Points |
|
UEECD0010 |
Compile and produce an energy sector detailed report |
60 |
UEECD0024 |
Implement and monitor energy sector WHS policies and procedures |
20 |
UEECD0027 |
Participate in development and follow a personal competency development plan |
20 |
UEERA0049 |
Install and start up single head split air conditioning and water heating heat pump systems* |
70 |
UEERA0059 |
Prepare and connect refrigerant tubing and fittings* |
40 |
UEERA0064 |
Recover, pressure test, evacuate, charge and leak test refrigerants - split systems* |
60 |
UEERE0015 |
Implement and monitor energy sector environmental and sustainable policies and procedures |
20 |
Group A: Imported and common elective units |
Weighting Points |
|
BSBOPS203 |
Deliver a service to customers |
20 |
CPCWHS1001 |
Prepare to work safely in the construction industry |
10 |
HLTAID009 |
Provide cardiopulmonary resuscitation |
10 |
ICTICT214 |
Operate application software packages |
20 |
UEECD0011 |
Comply with scheduled and preventative maintenance program processes |
20 |
UEECD0035 |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
UEECO0002 |
Maintain documentation |
20 |
UEECO0015 |
Provide quotations for installation or service jobs |
20 |
UEECO0017 |
Source and purchase material/parts for installation or service jobs |
20 |
Group B: Qualification elective units |
Weighting Points |
|
UEECS0033 |
Use engineering applications software on personal computers |
40 |
UEEIC0002 |
Assemble, enter and verify operating instructions in microprocessor equipped devices* |
20 |
UEEIC0013 |
Develop, enter and verify discrete control programs for programmable controllers* |
60 |
UEERA0036 |
Establish the basic operating conditions of vapour compression systems* |
60 |
UEERA0035 |
Establish the basic operating conditions of air conditioning systems* |
20 |
UEERA0007 |
Apply safety awareness and legal requirements for flammable refrigerants |
10 |
Group C: Qualification elective units |
Weighting Points |
|
UEECD0047 |
Supervise and coordinate energy sector work activities |
40 |
UEEEL0029 |
Conduct compliance inspection of LV electrical installations with demand exceeding 100 A per phase* |
40 |
UEEEL0030 |
Conduct compliance inspection of single phase LV electrical installations* |
60 |
UEERA0002 |
Analyse the psychrometric performance of HVAC/R systems* |
50 |
UEERA0003 |
Analyse the thermodynamic performance of HVAC/R systems |
50 |
Qualification Mapping Information
This qualification replaces and is not equivalent to UEE40511 Certificate IV in Electrical - Air-conditioning Split Systems |
Links
Companion Volume Implementation Guides are found in VETNet - https://vetnet.gov.au/Pages/TrainingDocs.aspx?q=b8a8f136-5421-4ce1-92e0-2b50341431b6