Description
Scope
This qualification provides competencies to select, install, commission, fault find and maintain electrical and instrumentation equipment in buildings and premises and instrumentation systems and core instrumentation equipment for process and control. It includes ERAC requirements for an ‘Electrician’s licence’.
Pathways Information
Not applicable.
Licensing/Regulatory Information
Not applicable.
Entry Requirements
Not applicable.
Employability Skills Summary
Not applicable.
Packaging Rules
Completion requirements
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- All the Core competency standard units, defined in the Core Competency Standard Units table below and
- A combination of Elective competency standard units to achieve a total weighting of 120 points in accordance with the Elective Competency Standard Units table below.
Note: UEENEEG105A - Those holding an ‘Unrestricted Electricians Licence or equivalent issued in an Australian State or Territory meets the requirements of this unit and its pre-requisite requirements.
Core Competency Standard Units All Core competency standard units to be achieved |
Weighting Points |
|
UEENEEE038B |
Participate in development and follow a personal competency development plan |
20 |
UEENEEE101A |
Apply Occupational Health Safety regulations, codes and practices in the workplace |
20 |
UEENEEE102A |
Fabricate, dismantle, assemble of utilities industry components |
40 |
UEENEEE104A |
Solve problems in d.c. circuits |
80 |
UEENEEE105A |
Fix and secure electrotechnology equipment |
20 |
UEENEEE107A |
Use drawings, diagrams, schedules, standards, codes and specifications |
40 |
UEENEEE117A |
Implement and monitor OHS procedures and policies |
20 |
UEENEEE124A |
Compile and produce an electrotechnology/ utilities report |
60 |
UEENEEE137A |
Document and apply measures to control OHS risks associated with electrotechnology work |
20 |
UEENEEG006A |
Solve problems in single and three phase low voltage machines |
80 |
UEENEEG033A |
Solve problems in single and three phase low voltage electrical apparatus and circuits |
60 |
UEENEEG063A |
Arrange circuits, control and protection for general electrical installations |
40 |
UEENEEG101A |
Solve problems in electromagnetic devices and related circuits |
60 |
UEENEEG102A |
Solve problems in low voltage a.c. circuits |
80 |
UEENEEG103A |
Install low voltage wiring and accessories |
20 |
UEENEEG104A |
Install appliances, switchgear and associated accessories for low voltage electrical installations |
20 |
UEENEEG105A |
Verify compliance and functionality of low voltage general electrical installations |
40 |
UEENEEG106A |
Terminate cables, cords and accessories for low voltage circuits |
40 |
UEENEEG107A |
Select wiring systems and cables for low voltage general electrical installations |
60 |
UEENEEG108A |
Trouble-shoot and repair faults in low voltage electrical apparatus and circuits |
40 |
UEENEEG109A |
Develop and connect electrical control circuits |
80 |
UEENEEI101A |
Use instrumentation drawings, specifications, standards and equipment manuals |
40 |
UEENEEI102A |
Solve problems in pressure measurement circuits and systems |
40 |
UEENEEI103A |
Solve problems in density/level measurement circuits and systems |
40 |
UEENEEI104A |
Solve problems in flow measurement circuits and systems |
40 |
UEENEEI105A |
Solve problems in temperature measurement circuits and systems |
40 |
UEENEEK145A |
Implement and monitor energy sector policies and procedures for environmental and sustainable work practices |
20 |
Total points in core |
1160 |
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 120 points from the following groups: |
|||
Group |
Minimum points |
Maximum points |
|
A |
Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. |
0 |
60 |
B |
Qualification Elective Units |
0 |
60 |
C |
Qualification Elective Units You may select all your elective units from this Group |
60 |
120 |
Group A – Imported and Common Elective Units You may complete units to a maximum weighting of 60 |
Weighting Points |
|
UEENEEC001B |
Maintain documentation |
20 |
UEENEEC002B |
Source and purchase material/parts for installation or service jobs |
20 |
UEENEEC003B |
Provide quotations for installation or service jobs |
20 |
UEENEEC010B |
Deliver a service to customers |
20 |
UEENEED101A |
Use basic computer applications relevant to a electrotechnology workplace |
20 |
UEENEEE009B |
Comply with scheduled and preventative maintenance program processes |
20 |
UEENEEE020B |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
CPCCOHS1001A |
Work safely in the construction industry |
10 |
HLTCPR201B |
Perform CPR |
10 |
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework |
Up to 60 points |
|
Group B – Qualification Elective Units You may complete units to a maximum weighting of 60 |
Weighting Points |
|
UEENEED104A |
Use software for engineering applications |
40 |
UEENEEG118A |
Maintain operation of electrical mining equipment and systems |
60 |
UEENEEG119A |
Maintain the operation of electrical marine equipment and systems |
60 |
UEENEEH102A |
Repair basic electronic apparatus faults by replacement of components |
40 |
UEENEEH111A |
Troubleshoot single phase input d.c. power supplies |
40 |
UEENEEI106A |
Set up and adjust PID process control loops |
40 |
UEENEEI107A |
Install process instrumentation and tubing and control cabling |
20 |
UEENEEI108A |
Install process control apparatus and associated equipment |
20 |
UEENEEI110A |
Set up and adjust advanced process control loops |
40 |
UEENEEI111A |
Find and rectify faults in process final control elements |
40 |
UEENEEI113A |
Setup and configure human-machine interface (HMI) and industrial networks |
60 |
UEENEEI116A |
Enter and verify operating instructions in microprocessor equipped devices |
20 |
UEENEEI140A |
Plan the electrical installation of integrated systems |
20 |
UEENEEI141A |
Develop electrical integrated systems |
20 |
UEENEEI150A |
Develop, enter and verify discrete control programs for programmable controllers |
60 |
UEENEEM019A |
Attend to breakdowns in hazardous areas — coal mining |
20 |
UEENEEM020A |
Attend to breakdowns in hazardous areas — gas atmospheres |
20 |
UEENEEM021A |
Attend to breakdowns in hazardous areas — dust atmospheres |
20 |
UEENEEM022A |
Attend to breakdowns in hazardous areas — pressurisation |
20 |
UEENEEM023A |
Install explosion-protected equipment and wiring systems — coal mining |
60 |
UEENEEM024A |
Install explosion-protected equipment and wiring systems — gas atmospheres |
60 |
UEENEEM025A |
Install explosion-protected equipment and wiring systems — dust atmospheres |
60 |
UEENEEM026A |
Install explosion-protected equipment and wiring systems — pressurisation |
60 |
UEENEEM027A |
Maintain equipment in hazardous areas — coal mining |
60 |
UEENEEM028A |
Maintain equipment in hazardous areas — gas atmospheres |
60 |
UEENEEM029A |
Maintain equipment in hazardous areas — dust atmospheres |
60 |
UEENEEM030A |
Maintain equipment in hazardous areas — pressurisation |
60 |
UEENEEM038A |
Conduct testing of hazardous areas installations — coal mining |
40 |
UEENEEM039A |
Conduct testing of hazardous areas installations — gas atmospheres |
40 |
UEENEEM040A |
Conduct testing of hazardous areas installations — dust atmospheres |
40 |
UEENEEM041A |
Conduct testing of hazardous area installations — pressurisation |
40 |
UEENEEM042A |
Conduct visual inspection of hazardous areas installations |
40 |
UEENEEM076A |
Use and maintain the integrity of a portable gas detection device |
20 |
UEENEEM077A |
Install and maintain the integrity of fixed gas detection equipment |
20 |
UEENEEM080A |
Report on the integrity of explosion-protected equipment in a hazardous area |
20 |
Group C – Qualification Elective Units You must complete units to a minimum weighting of 60 You may select all your elective units from this Group |
Weighting Points |
|
UEENEEI119A |
Set up transducers and field control devices |
60 |
UEENEEI120A |
Provide solutions to problems in industrial control systems |
60 |
UEENEEI124A |
Diagnose and rectify faults in electronic control systems |
60 |
UEENEEI125A |
Provide solutions to fluid circuit operations |
60 |
UEENEEI126A |
Provide solutions to pneumatic/hydraulic system operations |
80 |
UEENEEI139A |
Diagnose and rectify faults in digital controls systems |
60 |
UEENEEI148A |
Provide solutions to single phase electronic power control problems |
60 |
UEENEEI149A |
Provide solutions to polyphase electronic power control problems |
60 |
UEENEEI151A |
Develop, enter and verify programs for industrial control systems using high level instructions |
60 |
UEENEEI152A |
Develop, enter and verify programs in Supervisory Control and Data Acquisition systems |
60 |
Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.
END OF QUALIFICATION
Custom Content Section
Not applicable.