Qualification details

UEE33011 - Certificate III in Electrical Fitting (Release 2)

Summary

Usage recommendation:
Superseded
Mapping:
MappingNotesDate
Is superseded by UEE33020 - Certificate III in Electrical Fitting 04/Oct/2020

Releases:
ReleaseRelease date
(View details for release 4) 17/Apr/2014
(View details for release 3) 14/Aug/2013
2 (this release) 06/Mar/2013
(View details for release 1) 16/Mar/2012

Replaced release

You are currently viewing the components related to release 2.
The current release is release 4View release 4 details.

Units of competency

CodeSort Table listing Units of Competency by the Code columnTitleSort Table listing Units of Competency by the Title columnUsage RecommendationSort Table listing Units of Competency by the Usage Recommendation columnEssentialSort Table listing Units of Competency by the Essential column
UEENEEI108A - Install instrumentation and control apparatus and associated equipmentInstall instrumentation and control apparatus and associated equipmentSupersededN/A
UEENEEJ105A - Position, assemble and start up single head split air conditioning and water heating heat pump systemsPosition, assemble and start up single head split air conditioning and water heating heat pump systemsSupersededN/A
UEENEEA110A - Assemble, mount and connect control gear and switchgearAssemble, mount and connect control gear and switchgearSupersededN/A
UEENEEC003B - Provide quotations for installation or service jobsProvide quotations for installation or service jobsSupersededN/A
UEENEEP021A - Disconnect - reconnect explosion-protected appliances and control devices connected to low voltage installation wiringDisconnect - reconnect explosion-protected appliances and control devices connected to low voltage installation wiringSupersededN/A
UEENEED101A - Use computer applications relevant to a workplaceUse computer applications relevant to a workplaceDeletedN/A
UEENEEG119A - Maintain operation of electrical marine equipment and systemsMaintain operation of electrical marine equipment and systemsSupersededN/A
UEENEEM063A - Carry out overhaul and repair of explosion-protected equipment - dust atmospheresCarry out overhaul and repair of explosion-protected equipment - dust atmospheresDeletedN/A
UEENEEG167A - Align and install traction lift equipmentAlign and install traction lift equipmentSupersededN/A
UEENEEM034A - Overhaul and repair of explosion-protected equipment - dust atmospheresOverhaul and repair of explosion-protected equipment - dust atmospheresDeletedN/A
Items per page 10 | 20 | 50 | 100
Displaying items 1 - 10 of 121

Classifications

SchemeCodeClassification value
ANZSCO Identifier 341111 Electrician (General) 
ASCO (occupation type) Identifier 4311-11 General Electrician 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 
Qualification/Course Level of Education Identifier 514 Certificate III 
Taxonomy - Industry Sector N/A Electricity Generation Maintenance 
Taxonomy - Occupation N/A Electrician (Hazardous Areas),Instrumentation Fitter (Hazardous Areas),Switchgear Tradesperson,Electrician (Explosion Equipment) 

Classification history

SchemeCodeClassification valueStart dateEnd date
ANZSCO Identifier 341111 Electrician (General) 07/Aug/2012 
ASCO (occupation type) Identifier 4311-11 General Electrician 07/Aug/2012 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 07/Aug/2012 
Qualification/Course Level of Education Identifier 514 Certificate III 16/Mar/2012 
The content being displayed has been produced by a third party, while all attempts have been made to make this content as accessible as possible it cannot be guaranteed. If you are encountering issues following the content on this page please consider downloading the content in its original form

Modification History

Release

Action

Core/Elective

Details

Points

2

Add

Group B

UETTDRIS67A Solve problems in energy supply network equipment

80

2

Add

Group B

UETTDRIS68A Solve problems in energy supply network protection equipment and systems

40

2

Add

Group B

UETTDRIS44A Perform HV field switching operation to a given schedule

60

2

Update

Group A

HLTCPR211A Perform CPR

10

2

Update

Group A

HLTFA311A Apply first aid

10

2

Edit

Edit Name to reflect correct Unit title

UEENEED104A Use engineering applications software on personal computers

40

Description

Scope 

This qualification provides competencies to manufacture, fit, assemble, erect, operate, test, fault find, alter, repair electrical equipment and includes electrical wiring work only if that work is associated with assembling, maintaining, terminating or altering the wiring between electrical components within a plant or machinery. An electrical fitter is not authorised to install any electrical wiring systems within an electrical installation as prescribed by definitions contained in AS/NZS 3000.

Electrical equipment means any appliance, article, accessory, wire, fitting, cable, conduit or apparatus that generates, uses, conveys or controls (or that is intended to generate, use, convey or control) electricity above extra low voltage.

Pathways Information

Not applicable.

Licensing/Regulatory Information

Not applicable.

Entry Requirements

Not applicable.

Employability Skills Summary

Not applicable.

Packaging Rules

Completion requirements 

The requirements for granting this qualification will be met when competency is demonstrated and achieved for:

  • All the Core competency standard units, defined in the Core Competency Standard Units table below and
  • A combination of Elective competency standard units to achieve a total weighting of 240 points in accordance with the Elective Competency Standard Units table below.

Core Competency Standard Units  

All Core competency standard units to be achieved

Weighting 

Points 

UEENEEC020B

Participate in electrical competency development plan

60

UEENEEE101A

Apply Occupational Health Safety regulations, codes and practices in the workplace

20

UEENEEE102A

Fabricate, dismantle, assemble utilities components

40

UEENEEE104A

Solve problems in d.c. circuits

80

UEENEEE105A

Fix and secure electrotechnology equipment

20

UEENEEE107A

Use drawings, diagrams, schedules, standards, codes and specifications

40

UEENEEE137A

Document and apply measures to control OHS risks associated with electrotechnology work

20

UEENEEG006A

Solve problems in single and three phase low voltage machines

80

UEENEEG033A

Solve problems in single and three phase low voltage electrical apparatus and circuits

60

UEENEEG063A

Arrange circuits, control and protection for general electrical installations

40

UEENEEG101A

Solve problems in electromagnetic devices and related circuits

60

UEENEEG102A

Solve problems in low voltage a.c. circuits

80

UEENEEG106A

Terminate cables, cords and accessories for low voltage circuits

40

UEENEEG108A

Trouble-shoot and repair faults in low voltage electrical apparatus and circuits

40

UEENEEG109A

Develop and connect electrical control circuits

80

UEENEEG199A

Verify compliance and functionality of existing circuits

40

UEENEEK142A

Apply environmental and sustainable procedures in the energy sector

20

Total points in core 

820  

Elective Competency Standard Units 

Complete Elective units to achieve a total of weighting of 240 points from the following groups:

Group 

Minimum points 

Maximum points 

A 

Imported and Common Elective Units 

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 3. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

0

60

B 

Qualification Elective Units 

You may select all your elective units from this Group

180

240

Group A – Imported and Common Elective Units 

You may complete units to a maximum weighting of 60

Weighting Points 

UEENEEC001B

Maintain documentation

20

UEENEEC002B

Source and purchase material/parts for installation or service jobs

20

UEENEEC003B

Provide quotations for installation or service jobs

20

UEENEEC010B

Deliver a service to customers

20

UEENEED101A

Use basic computer applications relevant to a workplace

20

UEENEEE009B

Comply with scheduled and preventative maintenance program processes

20

UEENEEE020B

Provide basic instruction in the use of electrotechnology apparatus

20

CPCCOHS1001A

Work safely in the construction industry

10

HLTCPR211A

Perform CPR

10

HLTFA311A

Apply first aid

10

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 3. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework

Up to 60 points

Group B – Qualification Elective Units 

Complete units to a minimum weighting of 180

You may select all your elective units from this Group

Weighting Points 

UEENEEA110A

Assemble, mount and connect switchgear and controlgear

40

UEENEEA112A

Make up and assemble bus bars

60

UEENEEA113A

Assemble and wire control panels

40

UEENEED104A

Use engineering applications software on personal computers

40

UEENEEF102A

Install and maintain cabling for multiple access to telecommunication services

120

UEENEEF104A

Install and modify performance data communication copper cabling

40

UEENEEF115A

Assemble and connect telecommunication frames and cabinets

60

UEENEEG110A

Diagnose and rectify faults in d.c. electrical apparatus and circuits

60

UEENEEG111A

Carry out repairs to electrical apparatus

40

UEENEEG116A

Diagnose and rectify faults in lifts/escalator systems

80

UEENEEG118A

Maintain operation of electrical mining equipment and systems

60

UEENEEG119A

Maintain the operation of electrical marine equipment and systems

60

UEENEEG129A

Overhaul and repair switchgear and controlgear

60

UEENEEG150A

Wind electrical coils

40

UEENEEG151A

Place and connect electrical coils

40

UEENEEG152A

Rewind single phase machines

40

UEENEEG153A

Rewind LV three phase induction machines rated for low voltage

60

UEENEEG154A

Rewind LV direct current machines

60

UEENEEG157A

Conduct electrical tests on LV electrical machines

40

UEENEEG159A

Conduct mechanical tests of LV electrical machines

40

UEENEEG164A

Repair mechanical and electrical components of electrical machines

40

UEENEEG165A

Maintain and service electrical traction lifts

40

UEENEEG166A

Installation and maintenance of escalators, tread ways and moving walks

40

UEENEEG167A

Align and install lift components and equipment

20

UEENEEG181A

Provide advice on effective and energy efficient lighting products

20

UEENEEG182A

Supply effective and efficient lighting products for domestic and small commercial applications

40

UEENEEG183A

Provide advice on the application of energy efficient lighting for ambient and aesthetic effect

20

UEENEEH102A

Repair basic electronic apparatus faults by replacement of components

40

UEENEEH111A

Troubleshoot single phase input d.c. power supplies

40

UEENEEI101A

Use instrumentation drawings, specifications, standards and equipment manuals

40

UEENEEI102A

Solve problems in pressure measurement circuits and systems

40

UEENEEI103A

Solve problems in density/level measurement circuits and systems

40

UEENEEI104A

Solve problems in flow measurement circuits and systems

40

UEENEEI105A

Solve problems in temperature measurement circuits and systems

40

UEENEEI107A

Install process instrumentation and tubing and control cabling

20

UEENEEI108A

Install process control apparatus and associated equipment

20

UEENEEI116A

Enter and verify operating instructions in microprocessor equipped devices

20

UEENEEI150A

Develop, enter and verify discrete control programs for programmable controllers

60

UEENEEJ102A

Prepare and connect refrigerant tubing and fittings

30

UEENEEJ103A

Establish the basic operating conditions of vapour compression systems

60

UEENEEJ104A

Establish the basic operating conditions of air conditioning systems

20

UEENEEJ105A

Position, assemble and start up single head split air conditioning and water heating heat pump systems

70

UEENEEJ106A

Install refrigerant pipe work, flow controls and accessories

60

UEENEEJ108A

Recover, pressure test, evacuate, charge and leak test refrigerants

60

UEENEEJ151A

Service small electrical appliances and power tools

60

UEENEEJ153A

Find and rectify fault motors and associated controls in refrigeration and air conditioning

50

UEENEEJ154A

Find and rectify faults in appliance control systems and devices

60

UEENEEJ155A

Service refrigeration appliances

60

UEENEEJ156A

Service clothes washing machines and dryers

40

UEENEEJ157A

Service electrical heating appliances

60

UEENEEJ158A

Service dishwasher machines

40

UEENEEJ159A

Service gas heating appliances

40

UEENEEJ162A

Recover, pressure test, evacuate, charge and leak test refrigerants — appliances

50

UEENEEJ170A

Diagnose and rectify faults in air conditioning and refrigeration control systems

70

UEENEEJ173A

Service and repair microwave ovens

40

UEENEEJ194A

Solve problems in low voltage refrigeration circuits

40

UEENEEJ195A

Establish the basic operating conditions of vapour compression systems - appliances

50

UEENEEM019A

Attend to breakdowns in hazardous areas — coal mining

20

UEENEEM020A

Attend to breakdowns in hazardous areas — gas atmospheres

20

UEENEEM021A

Attend to breakdowns in hazardous areas — dust atmospheres

20

UEENEEM022A

Attend to breakdowns in hazardous areas — pressurisation

20

UEENEEM027A

Maintain equipment in hazardous areas — coal mining

60

UEENEEM028A

Maintain equipment in hazardous areas — gas atmospheres

60

UEENEEM029A

Maintain equipment in hazardous areas — dust atmospheres

60

UEENEEM030A

Maintain equipment in hazardous areas — pressurisation

60

UEENEEM031A

Overhaul and repair of explosion-protected equipment — coal mining

60

UEENEEM032A

Overhaul and repair of explosion-protected equipment — flameproof enclosures

60

UEENEEM033A

Overhaul and repair of explosion-protected equipment — gas atmospheres

60

UEENEEM034A

Overhaul and repair of explosion-protected equipment — dust atmospheres

40

UEENEEM060A

Carry out overhaul and repair of explosion-protected equipment — coal mining

60

UEENEEM061A

Carry out overhaul and repair of explosion-protected equipment — flameproof enclosures

60

UEENEEM062A

Carry out overhaul and repair of explosion-protected equipment — gas atmospheres

60

UEENEEM063A

Carry out overhaul and repair of explosion-protected equipment — dust atmospheres

60

UEENEEM070A

Repair reeling, trailing and flexible cables

60

UEENEEM071A

Test reeling, trailing and flexible cables

60

UEENEEM072A

Inspect and fit plugs/couplers for reeling, trailing and flexible cables

60

UEENEEM073A

Verify compliance of repaired reeling, trailing and flexible cables

60

UEENEEM076A

Use and maintain the integrity of a portable gas detection device

20

UEENEEM077A

Install and maintain the integrity of fixed gas detection equipment

20

UEENEEM080A

Report on the integrity of explosion-protected equipment in a hazardous area

20

UEENEEN102A

Assemble and wire internal electrical rail signalling equipment

30

UEENEEN104A

Test rail signalling cables

20

UEENEEN121A

Repair rail signalling power and control cables

40

UEENEEP010A

Disconnect / reconnect appliances connected to low voltage installation wiring

60

UEENEEP011A

Disconnect / reconnect neon signs connected to low voltage installation wiring

60

UEENEEP014A

Disconnect / reconnect water heaters connected to low voltage installation wiring

60

UEENEEP016A

Locate and rectify faults in low voltage appliances using set procedures

20

UEENEEP019A

Locate and rectify faults in low voltage water heaters using set procedures

20

UEENEEP021A

Disconnect / reconnect explosion-protected appliances and control devices connected to low voltage installation wiring

60

UEENEEP022A

Disconnect and reconnect 3.3 kV electric propulsion components of self-propelled earth moving vehicles

60

UEENEEP023A

Attach flexible cables and plugs to electrical equipment connected to a HV supply

40

UETTDRIS43A

Perform low voltage field switching operation to a given schedule.

50

UETTDRIS44A

Perform high voltage field switching operation to a given schedule

40

UETTDRIS47A

Sample, test, filter and reinstate insulating oil

40

UETTDRIS67A

Solve problems in energy supply network equipment

80

UETTDRIS68A

Solve problems in energy supply network protection equipment and systems

40

UETTDRSB29A

Maintain capacitor bank equipment for voltage regulation

40

UETTDRSB39A

Perform power system substation switching operation to a given schedule

50

UETTDRIS67A

Solve problems in energy supply network equipment

80

UETTDRIS68A

Solve problems in energy supply network protection equipment and systems

40

UETTDRIS44A

Perform HV field switching operation to a given schedule

40

Note:  
1. Prerequisite pathways shall be identified and met for all elective units selected.

2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.

END OF QUALIFICATION 