Description
Scope
This qualification provides competencies to set-up, service and repair electrical and refrigerated appliances with electives in gas appliances.
Note: The Ozone Protection and Synthetic Greenhouse Gas Legislation Amendment Bill 2003 apply to this qualification. Prior to planning the delivery of any training and/or assessment activities all legislative and regulatory requirements shall be identified and included.
^ From 1 July 2022 the elective units HLTAID001, HLTAID003 must no longer be delivered and will be replaced in the Packaging Rules by the units HLTAID009, HLTAID011 - for more information see: https://asqa.gov.au/news-events/news/reminder-about-superseded-hlt-first-aid-units
Pathways Information
Not applicable.
Licensing/Regulatory Information
Not applicable.
Entry Requirements
Not applicable.
Employability Skills Summary
Not applicable.
Packaging Rules
Completion requirements
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- All the Core competency standard units, defined in the Core Competency Standard Units table below and
- A combination of Elective competency standard units to achieve a total weighting of 220 points in accordance with the Elective Competency Standard Units table below.
Core Competency Standard Units All Core competency standard units to be achieved |
||
UEENEEC017B |
Participate in appliance servicing work and competency development activities |
60 |
UEENEEE101A |
Apply Occupational Health and Safety regulations, codes and practices in the workplace |
20 |
UEENEEE102A |
Fabricate, assemble and dismantle utilities industry components |
40 |
UEENEEE103A |
Solve problems in ELV single path circuits |
40 |
UEENEEE105A |
Fix and secure electrotechnology equipment |
20 |
UEENEEE107A |
Use drawings, diagrams, schedules, standards, codes and specifications |
40 |
UEENEEE137A |
Document and apply measures to control OHS risks associated with electrotechnology work |
20 |
UEENEEJ102A |
Prepare and connect refrigerant tubing and fittings |
30 |
UEENEEJ151A |
Service small electrical appliances and power tools |
60 |
UEENEEJ153A |
Find and rectify faults in motors and associated controls in refrigeration and air conditioning systems |
50 |
UEENEEJ154A |
Find and rectify faults in appliance control systems and devices |
60 |
UEENEEJ155A |
Service refrigeration appliances |
60 |
UEENEEJ156A |
Service clothes washing machines and dryers |
40 |
UEENEEJ161A |
Verify functionality and compliance of appliances |
20 |
UEENEEJ162A |
Recover, pressure test, evacuate, charge and leak test refrigerants - appliances |
50 |
UEENEEJ194A |
Solve problems in low voltage refrigeration circuits |
40 |
UEENEEJ195A |
Establish the basic operating conditions of vapour compression systems - appliances |
50 |
UEENEEK142A |
Apply environmentally and sustainable procedures in the energy sector |
20 |
UEENEEP012A |
Disconnect / reconnect composite appliances connected to low voltage installation wiring |
60 |
UEENEEP017A |
Locate and rectify faults in low voltage composite appliances using set procedures |
20 |
UEENEEP024A |
Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply |
20 |
UEENEEP025A |
Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply |
20 |
Total points in core |
840 |
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 220 points from the following groups: |
||||
Group |
Minimum points |
Maximum points |
||
A |
Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 3. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. |
0 |
100 |
|
B |
Qualification Elective Units You may select all your elective units from this Group |
120 |
220 |
|
Group A – Imported and Common Elective Units You may complete units to a maximum weighting of 100 |
Weighting Points |
|||
UEENEEC001B |
Maintain documentation |
20 |
||
UEENEEC002B |
Source and purchase material/parts for installation or service jobs |
20 |
||
UEENEEC003B |
Provide quotations for installation or service jobs |
20 |
||
UEENEEC010B |
Deliver a service to customers |
20 |
||
UEENEED101A |
Use computer applications relevant to a workplace |
20 |
||
UEENEEE009B |
Comply with scheduled and preventative maintenance program processes |
20 |
||
UEENEEE020B |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
||
CPCCOHS1001A |
Work safely in the construction industry |
10 |
||
HLTAID001 ^ HLTAID009 |
Provide cardiopulmonary resuscitation Provide cardiopulmonary resuscitation (must be delivered from 1 July 2022) |
10 |
||
HLTAID003 ^ HLTAID011 |
Provide first aid Provide First Aid (must be delivered from 1 July 2022) |
10 |
||
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 3. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework |
Up to 100 points |
|||
Group B – Qualification Elective Units Complete units to a minimum weighting of 120 You may select all your elective units from this Group |
Weighting Points |
|||
UEENEEJ104A |
Establish the basic operating conditions of air conditioning systems |
20 |
||
UEENEEJ118A |
Resolve problems in post mix refrigeration systems |
20 |
||
UEENEEJ157A |
Service electrical heating appliances |
60 |
||
UEENEEJ158A |
Service dishwasher machines |
40 |
||
UEENEEJ159A |
Service gas heating appliances |
40 |
||
UEENEEJ171A |
Resolve problems in refrigerated beverage vending cabinets |
20 |
||
UEENEEJ173A |
Service and repair microwave ovens |
40 |
||
UEENEEJ174A |
Apply safety awareness and legal requirements for hydrocarbon refrigerants |
10 |
||
UEENEEJ175A |
Service and repair self contained hydrocarbon air conditioning and refrigeration systems |
20 |
||
UEENEEJ184A |
Apply safety awareness and legal requirements for carbon dioxide refrigerant |
10 |
||
UEENEEJ188A |
Repair and service self contained carbon dioxide refrigeration and heat pump systems |
20 |
||
UEENEEJ189A |
Service room air conditioners |
30 |
Note:
1. Pre-requisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a pre-requisite pathway for the progression to achieve particular competencies or qualification at a higher level.
END OF QUALIFICATION