Modification History
Not applicable.
Unit Descriptor
Unit descriptor |
This unit specifies the outcomes required to float a laminate, pre-finished or engineered timber floor within a space over a soft underlay including preparation, cutting, laying and fixing. |
Application of the Unit
Application of the unit |
This unit supports the attainment of skills and knowledge required for competent workplace performance in the wide variety of flooring technology operations. The competency applies to an on site environment and involves application of skills and knowledge at the sub-trade worker level. These skills and knowledge are to be used within the scope of the individual's job and authority. |
Licensing/Regulatory Information
Not applicable.
Pre-Requisites
Prerequisite units |
Nil |
|
Employability Skills Information
Employability skills |
This unit contains employability skills. |
Elements and Performance Criteria Pre-Content
Elements describe the essential outcomes of a unit of competency. |
Performance criteria describe the performance needed to demonstrate achievement of the element. Where bold italicised text is used, further information is detailed in the required skills and knowledge section and the range statement. Assessment of performance is to be consistent with the evidence guide. |
Elements and Performance Criteria
ELEMENT |
PERFORMANCE CRITERIA |
1. Prepare materials for installation |
1.1. Applicable legislative, OHS and organisational requirements relevant to the installing laminate and engineered timber flooring are verified and complied with 1.2. Workplace health and safety requirements, including personal protection needs, are observed throughout the work 1.3. Instructions and/or plans are read and interpreted to identify process required to complete work tasks 1.4. Sub-floor condition is assessed for suitability for installation of laminate and engineered timber flooring 1.5. Tools, equipment and materials are selected and checked prior to use to ensure that they are appropriate for the work, serviceable and in a safe condition 1.6. Sequence of work is planned, including the selection of a starting point, to ensure efficiency and quality of installation |
2. Set out materials for installation |
2.1. Laminate and engineered timber flooring is acclimatised according to manufacturer recommendations 2.2. Laminate and engineered timber flooring for fixing is organised and used in accordance with relevant safety management requirements 2.3. Skirting boards or cover trims are removed or undercut if required and stored for refitting or sent for machining 2.4. Adhesives and edge strips are prepared for use as required 2.5. Working lines and starting point are established |
3. Lay out flooring |
3.1. Instructions and sequence for laying and fixing are followed 3.2. Appropriate underlay is laid according to manufacturers' recommendations 3.3. Laminate and engineered timber flooring is laid out to meet directional sequence, pattern match, specification requirements and to minimise waste and joins 3.4. The aesthetics of the materials are maximised including matching grains and colours 3.5. Laminate and engineered timber flooring materials are accurately and clearly marked for cutting 3.6. Materials are cut to length and size for final laying ensuring minimum waste |
4. Lay flooring |
4.1. Materials for fixing are organised and used in accordance with relevant safety management requirements 4.2. Adhesives and edge strips/accessories are prepared for use as required 4.3. Fixing methods and equipment are used following manufacturer recommendations 4.4. Appropriate field and perimeter expansion joints are allowed 4.5. Skirting boards or cover trims are fitted/refitted and finished 4.6. Finished job is inspected and any imperfections are rectified following workplace procedures 4.7. Any required preparations for sanding of flooring are made |
5. Complete housekeeping |
5.1. Unused materials are stored or recycled as required 5.2. Tools and equipment are cleaned and stored appropriately 5.3. Work area is cleaned and rubbish is disposed of appropriately 5.4. Workplace documentation is completed |
Required Skills and Knowledge
REQUIRED SKILLS AND KNOWLEDGE |
This section describes the skills and knowledge required for this unit. |
Required skills |
|
Required knowledge |
|
Evidence Guide
EVIDENCE GUIDE |
|
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package. |
|
Critical aspects for assessment and evidence required to demonstrate competency in this unit |
|
Context of , and specific resources for assessment |
|
Method of assessment |
Assessment must satisfy the endorsed assessment guidelines of the Furnishing Industry Training Package Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application Assessment may be applied under project related conditions (real or simulated) and require evidence of process Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances Assessment may be in conjunction with assessment of other units of competency |
Range Statement
RANGE STATEMENT |
|
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included. |
|
Legislative requirements |
|
OHS requirements |
|
Organisational requirements |
|
Laminate and engineered timber flooring |
|
Instructions |
|
Sub-floor assessment |
|
Tools and equipment |
|
Materials |
|
Adhesives |
|
Unit Sector(s)
Unit sector |
Flooring Technology |
Competency field
Competency field |
Timber |
Co-requisite units
Co-requisite units |
||