Modification History
Release |
Action |
Core/Elective |
Details |
Points |
Edit |
Edit Name to Reflect correct Unit Title UEENEEI124A Fault find and repair analogue circuits and components in electronic control systems |
|||
2 |
Update |
Group A |
HLTCPR211A Perform CPR |
10 |
3 |
Edit |
Group C |
Edit Name to reflect correct Unit title UEENEEI151A Develop, enter and verify word and analogue control programs for programmable logic controllers. |
60 |
3 |
Edit |
Core |
Edit Name to reflect correct Unit title UEENEEK145A Implement and monitor energy sector environmental and sustainable policies and procedures |
20 |
4 |
Update |
Elective |
HLTAID001 - Provide cardiopulmonary resuscitation |
10 |
4 |
Edit |
Core |
Correct title of UEENEEE101A - Apply Occupational Health and Safety regulations, codes and practices in the workplace |
20 |
4 |
Edit |
Core |
Correct title of UEENEEE102A - Fabricate, assemble and dismantle utilities industry components |
40 |
4 |
Edit |
Core |
Correct title of UEENEEG116A - Diagnose and rectify faults in traction lift systems |
80 |
4 |
Edit |
Core |
Correct title of UEENEEG168A - Diagnose and rectify faults in complex lift systems |
40 |
4 |
Edit |
Elective |
Correct title of UEENEED101A - Use computer applications relevant to a workplace |
20 |
4 |
Edit |
Elective |
Correct title of UEENEEG110A - Find and repair faults in LV d.c. electrical apparatus and circuits |
60 |
4 |
Edit |
Elective |
Correct title of UEENEEG165A - Maintain and service traction lifts systems and equipment |
40 |
4 |
Edit |
Elective |
Correct title of UEENEEG166A - Install and maintain escalators, moving walks and treadways |
40 |
4 |
Edit |
Elective |
Correct title of UEENEEG167A - Align and install traction lift equipment |
20 |
4 |
Edit |
Elective |
Correct title of UEENEEI148A - Solve problems in single phase electronic power control circuits |
60 |
4 |
Edit |
Elective |
Correct title of UEENEEI149A - Solve problems in polyphase electronic power control circuits |
60 |
Description
Scope
This qualification provides competencies to select, install, commission, fault find and maintain lifts, escalators and associated equipment. It includes ERAC requirements for an ‘Electrician’s licence’.
Pathways Information
Not applicable.
Licensing/Regulatory Information
Not applicable.
Entry Requirements
Not applicable.
Employability Skills Summary
Not applicable.
Packaging Rules
Completion requirements
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- All the Core competency standard units, defined in the Core Competency Standard Units table below and
- A combination of Elective competency standard units to achieve a total weighting of 80 points in accordance with the Elective Competency Standard Units table below.
Note: UEENEEG105A - Those holding an ‘Unrestricted Electricians Licence or equivalent issued in an Australian State or Territory meets the requirements of this unit and its pre-requisite requirements.
Core Competency Standard Units All Core competency standard units to be achieved |
Weighting Points |
|
UEENEEE038B |
Participate in development and follow a personal competency development plan |
20 |
UEENEEE101A |
Apply Occupational Health Safety regulations, codes and practices in the workplace |
20 |
UEENEEE102A |
Fabricate, dismantle, assemble of utilities industry components |
40 |
UEENEEE104A |
Solve problems in d.c. circuits |
80 |
UEENEEE105A |
Fix and secure electrotechnology equipment |
20 |
UEENEEE107A |
Use drawings, diagrams, schedules, standards, codes and specifications |
40 |
UEENEEE117A |
Implement and monitor energy sector OHS policies and procedures |
20 |
UEENEEE124A |
Compile and produce an energy sector detailed report |
60 |
UEENEEE137A |
Document and apply measures to control OHS risks associated with electrotechnology work |
20 |
UEENEEG006A |
Solve problems in single and three phase low voltage machines |
80 |
UEENEEG033A |
Solve problems in single and three phase low voltage electrical apparatus and circuits |
60 |
UEENEEG063A |
Arrange circuits, control and protection for general electrical installations |
40 |
UEENEEG101A |
Solve problems in electromagnetic devices and related circuits |
60 |
UEENEEG102A |
Solve problems in low voltage a.c. circuits |
80 |
UEENEEG103A |
Install low voltage wiring and accessories |
20 |
UEENEEG104A |
Install appliances, switchgear and associated accessories for low voltage electrical installations |
20 |
UEENEEG105A |
Verify compliance and functionality of low voltage general electrical installations |
40 |
UEENEEG106A |
Terminate cables, cords and accessories for low voltage circuits |
40 |
UEENEEG107A |
Select wiring systems and cables for low voltage general electrical installations |
60 |
UEENEEG108A |
Trouble-shoot and repair faults in low voltage electrical apparatus and circuits |
40 |
UEENEEG109A |
Develop and connect electrical control circuits |
80 |
UEENEEG116A |
Diagnose and rectify faults in traction lift systems |
80 |
UEENEEG168A |
Diagnose and rectify faults in complex lift systems |
40 |
UEENEEI124A |
Fault find and repair analogue circuits and components in electronic control systems |
60 |
UEENEEI139A |
Diagnose and rectify faults in digital controls systems |
60 |
UEENEEK145A |
Implement and monitor energy sector environmental and sustainable policies and procedures |
20 |
Total points in core |
1200 |
Elective Competency Standard Units Complete Elective units to achieve a total of weighting of 80 points from the following groups: |
|||
Group |
Minimum points |
Maximum points |
|
A |
Imported and Common Elective Units Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. |
0 |
20 |
B |
Qualification Elective Units |
0 |
20 |
C |
Qualification Elective Units You may select all your elective units from this Group |
60 |
60 |
Group A – Imported and Common Elective Units You may complete units to a maximum weighting of 20 |
Weighting Points |
|
UEENEEC001B |
Maintain documentation |
20 |
UEENEEC002B |
Source and purchase material/parts for installation or service jobs |
20 |
UEENEEC003B |
Provide quotations for installation or service jobs |
20 |
UEENEEC010B |
Deliver a service to customers |
20 |
UEENEED101A |
Use computer applications relevant to a workplace |
20 |
UEENEEE009B |
Comply with scheduled and preventative maintenance program processes |
20 |
UEENEEE020B |
Provide basic instruction in the use of electrotechnology apparatus |
20 |
CPCCOHS1001A |
Work safely in the construction industry |
10 |
HLTAID001 |
Provide cardiopulmonary resuscitation |
10 |
Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points. Note: For further information see Application of the NQC Flexibility Formula, UEE11 Electrotechnology Training Package, Version 1, Volume 1 Qualification Framework |
Up to 20 points |
|
Group B – Qualification Elective Units You may complete units to a maximum weighting of 20 |
Weighting Points |
|
UEENEEF103A |
Install and maintain telecommunication cabling for services in lifts |
20 |
UEENEEG110A |
Find and repair faults in LV d.c. electrical apparatus and circuits |
60 |
UEENEEG165A |
Maintain and service traction lifts systems and equipment |
40 |
UEENEEG166A |
Install and maintain escalators, moving walks and treadways |
40 |
UEENEEG167A |
Align and install traction lift equipment |
20 |
UEENEEI150A |
Develop, enter and verify discrete control programs for programmable controllers |
60 |
Group C – Qualification Elective Units Complete units to a maximum weighting of 60 |
Weighting Points |
|
UEENEEI148A |
Solve problems in single phase electronic power control circuits |
60 |
UEENEEI149A |
Solve problems in polyphase electronic power control circuits |
60 |
UEENEEI151A |
Develop, enter and verify word and analogue control programs for programmable logic controllers. |
60 |
UEENEEI152A |
Develop, enter and verify programs in Supervisory Control and Data Acquisition systems |
60 |
Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.
END OF QUALIFICATION
Custom Content Section
Not applicable.