^

 
 

Qualification details

UEE31710 - Certificate III in Hazardous areas - Electrician (Release 1)

Summary

Usage recommendation:
Deleted
The Deleted usage recommendation was implemented on 13 June 2017 to describe training components that have no replacement. Enrolments in training components and statements of attainment or qualifications issued before 13 June 2017 are valid. For any components marked as deleted after 13 June 2017, the applicable transition/teach-out periods apply. For specific questions regarding the enrolment, delivery or issuance of a statement of attainment/qualification, please contact your training regulator.
Mapping:
MappingNotesDate
DeletedDeleted from UEE07 Electrotechnology Training Package15/Mar/2012
Supersedes and is equivalent to UEE31707 - Certificate III in Hazardous areas - Electrician28/Jul/2011

Releases:
ReleaseRelease date
1 1 (this release) 29/Jul/2011

Units of competency

CodeSort Table listing Units of Competency by the Code columnTitleSort Table listing Units of Competency by the Title columnUsage RecommendationSort Table listing Units of Competency by the Usage Recommendation columnEssentialSort Table listing Units of Competency by the Essential column
UEENEEC003B - Provide quotations for installation or service jobsProvide quotations for installation or service jobsSupersededN/A
UEENEEG001B - Solve problems in electromagnetic circuitsSolve problems in electromagnetic circuitsSupersededN/A
UEENEEG005B - Verify compliance and functionality of general electrical installationsVerify compliance and functionality of general electrical installationsSupersededN/A
UEENEEK042A - Participate in environmentally sustainable work practicesParticipate in environmentally sustainable work practicesSupersededN/A
UEENEEG004B - Install low voltage electrical apparatus and associated equipmentInstall low voltage electrical apparatus and associated equipmentSupersededN/A
UEENEEM038A - Conduct testing of hazardous areas installations - coal miningConduct testing of hazardous areas installations - coal miningDeletedN/A
UEENEEM022A - Attend to breakdowns in hazardous areas - pressurisationAttend to breakdowns in hazardous areas - pressurisationDeletedN/A
UEENEEM076A - Use and maintain the integrity of a portable gas detection deviceUse and maintain the integrity of a portable gas detection deviceSupersededN/A
UEENEEM023A - Install explosion-protected equipment and wiring systems - coal miningInstall explosion-protected equipment and wiring systems - coal miningDeletedN/A
UEENEEE002B - Dismantle, assemble and fabricate electrotechnology componentsDismantle, assemble and fabricate electrotechnology componentsSupersededN/A
Items per page 10 | 20 | 50 | 100
Displaying items 1 - 10 of 44

Classifications

SchemeCodeClassification value
ANZSCO Identifier 341111 Electrician (General) 
ASCO (occupation type) Identifier 4311-11 General Electrician 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 
Qualification/Course Level of Education Identifier 514 Certificate III 
Taxonomy - Industry Sector N/A Electrotechnology 

Classification history

SchemeCodeClassification valueStart dateEnd date
ANZSCO Identifier 341111 Electrician (General) 12/Aug/2009 
ASCO (occupation type) Identifier 4311-11 General Electrician 12/Aug/2009 
ASCED Qualification/Course Field of Education Identifier 0313 Electrical And Electronic Engineering And Technology 12/Aug/2009 
Qualification/Course Level of Education Identifier 514 Certificate III 12/Aug/2009 
The content being displayed has been produced by a third party, while all attempts have been made to make this content as accessible as possible it cannot be guaranteed. If you are encountering issues following the content on this page please consider downloading the content in its original form

Modification History

Not Applicable

Description

Scope 

This qualification provides competencies to select, install, commission, fault find and maintain general electrical systems and equipment and install and test explosion-protected systems and equipment with endorsements in the various explosion protection techniques. It includes ERAC requirements for an 'Electrician's licence'.

Pathways Information

Not Applicable

Licensing/Regulatory Information

Not Applicable

Entry Requirements

Not Applicable

Employability Skills Summary

Not Applicable

Packaging Rules

Completion requirements 

The requirements for awarding this qualification are that the following are successfully achieved:

  • All of the Core competency standard units;
  • The required number of Stream Core competency standard units;
  • The required number of Elective competency standard units as prescribed in the respective Schedule; and
  • All the required pre-requisite competency standard units have been met as required.

Core Competency Standard Units 

All Core competency standard units to be achieved

UEENEEC028B

Participate in hazardous areas work and competency development activities

UEENEEE001B

Apply OHS practices in the workplace

UEENEEE002B

Dismantle, assemble and fabricate electrotechnology components

UEENEEE003B

Solve problems in extra-low voltage single path circuits

UEENEEE004B

Solve problems in multiple path d.c. circuits

UEENEEE005B

Fix and secure equipment

UEENEEE007B

Use drawings, diagrams, schedules and manuals

UEENEEE008B

Lay wiring/cabling and terminate accessories for extra-low voltage circuits

UEENEEE033B

Document occupational hazards and risks in electrical work

UEENEEG001B

Solve problems in electromagnetic circuits

UEENEEG002B

Solve problems in single and three phase low voltage circuits

UEENEEG003B

Install wiring and accessories for low voltage circuits

UEENEEG004B

Install low voltage electrical apparatus and associated equipment

UEENEEG005B

Verify compliance and functionality of general electrical installations

UEENEEG007B

Select and arrange equipment for general electrical installations

UEENEEG008B

Find and repair faults in electrical apparatus and circuits

UEENEEG009B

Develop and connect control circuits

UEENEEM080A

Report on the integrity of explosion-protected equipment in a hazardous area

Stream Core Competency Standard Units 

At least 2 of the following competency standard units to be achieved

UEENEEC001B

Maintain documentation

UEENEEC002B

Source and purchase material/parts for installation or service jobs

UEENEEC003B

Provide quotations for installation or service jobs

UEENEEC010B

Deliver a service to customers

UEENEED001B

Use basic computer applications relevant to a workplace

UEENEEE009B

Comply with scheduled and preventative maintenance program processes

UEENEEE020B

Provide basic instruction in the use of electrotechnology apparatus

UEENEEK042A

Participate in environmentally sustainable work practices

Elective Competency Standard Units 

In accordance with Schedules 3 which forms an integral part of this qualification, achieve a Unit Strand Total of at least 5.

Note : 1. Pre-requisite pathways shall be identified and met for all elective units selected.

2. In selecting elective units considerations to career planning advice should be given to units that form part of a pre-requisite pathway for the progression to achieve particular competencies or qualification at a higher level.

3. It is recommended that consideration be given to selecting from the following Units in meeting the elective requirements for this qualification:

UEENEEM076A Use and maintain the integrity of a portable gas detection device

UEENEEM077AInstall and maintain the integrity of fixed gas detection equipment

UEENEEM019A Attend to breakdowns in hazardous areas coal mining

UEENEEM020A Attend to breakdowns in hazardous areas gas atmospheres

UEENEEM021A Attend to breakdowns in hazardous areas dust atmospheres

UEENEEM022A Attend to breakdowns in hazardous areas pressurisation

UEENEEM023A Install explosion-protected equipment and wiring systems coal mining

UEENEEM024A Install explosion-protected equipment and wiring systems gas atmospheres

UEENEEM024A Install explosion-protected equipment and wiring systems dust atmospheres

UEENEEM026A Install explosion-protected equipment and wiring systems pressurisation

UEENEEM027A Maintain equipment in hazardous areas coal mining

UEENEEM028A Maintain equipment in hazardous areas gas atmospheres

UEENEEM029A Maintain equipment in hazardous areas dust atmospheres

UEENEEM030A Maintain equipment in hazardous areas pressurisation

UEENEEM038A Conduct testing of hazardous area installations coal mining

UEENEEM039A Conduct testing of hazardous area installations gas atmospheres

UEENEEM040A Conduct testing of hazardous area installations dust atmospheres

UEENEEM041A Conduct testing of hazardous area installations pressurisation

UEENEEM042A Conduct visual inspection of hazardous areas installations

END OF QUALIFICATION

______________________________________________________________________