Unit of competency details

ICTOPN602 - Manage dense wavelength division multiplexing transmission system (Release 1)

Summary

Usage recommendation:
Superseded
Mapping:
MappingNotesDate
Is superseded by and equivalent to ICTOPN606 - Manage dense wavelength division multiplexing transmission systems 18/Jan/2021
Supersedes and is equivalent to ICTOPN6125A - Manage dense wavelength division multiplexing transmission systemUpdated to meet standards for Training Packages 13/Jan/2016

Releases:
ReleaseRelease date
1 1 (this release) 14/Jan/2016


Classifications

SchemeCodeClassification value
ASCED Module/Unit of Competency Field of Education Identifier 031307 Communications Technologies  

Classification history

SchemeCodeClassification valueStart dateEnd date
ASCED Module/Unit of Competency Field of Education Identifier 031307 Communications Technologies  24/Jun/2016 
The content being displayed has been produced by a third party, while all attempts have been made to make this content as accessible as possible it cannot be guaranteed. If you are encountering issues following the content on this page please consider downloading the content in its original form

Unit of competency

Modification History

Release 

Comments 

Release 1

This version first released with ICT Information and Communications Technology Training Package Version 2.0.

Application

This unit describes the skills and knowledge required to manage a dense wavelength division multiplexing (DWDM) transmission system using graphical user interface (GUI) management software.

It applies to individuals who use high-level technical skills and network management software to manage network operations. It is often carried out at a central Network Operations Centre (NOC).

No licensing, legislative or certification requirements apply to this unit at the time of publication.

Unit Sector

Telecommunications – Optical Networks

Elements and Performance Criteria

Element 

Performance Criteria 

Elements describe the essential outcomes.

Performance criteria describe the performance needed to demonstrate achievement of the element.

1. Prepare to manage transmission system

1.1 Determine networking issues and requirements from appropriate person

1.2 Install network management software according to vendor instructions, including access, security and administration

1.3 Create a customised representation of the enterprise’s network topology

1.4 Set and configure thresholds for performance monitoring

1.5 Prepare a plan to integrate the DWDM management system into a broader network management system where applicable

2. Manage transmission system

2.1 Manage network using appropriate communications links

2.2 Monitor network for faults and performance and produce a fault and performance report

3. Use network management to report on the overall state of transmission system

3.1 Analyse performance monitoring data and alarm data

3.2 Prepare report and make recommendations based on analysis

3.3 Report on network degradation over a period of time

Foundation Skills

This section describes language, literacy, numeracy and employment skills incorporated in the performance criteria that are required for competent performance.

Skill 

Performance Criteria 

Description 

Reading

1.1, 1.2, 3.1

  • Interprets textual information from relevant sources to identify and plan for all job requirements and adhere to procedures and standards

Writing

2.2, 3.2, 3.3

  • Accurately completes standard reports and documentation using clear and technically specific language, numerical data and diagrammatic information

Oral Communication

1.1, 1.2, 3.3

  • Uses listening and questioning skills to confirm technical and operational requirements and participates in a verbal exchange of ideas and solutions and uses appropriate, detailed and clear language to address key personnel and clients

Numeracy

1.4, 3.1

  • Uses mathematical equations to evaluate technical data and determine acceptable monitoring levels

Get the work done

1.1-1.5, 2.1, 2.2

  • Sequences and schedules complex activities, monitors implementation and manages relevant communication
  • Takes responsibility for high-impact decisions in complex situations involving many variables and constraints
  • Uses nuanced understanding of context to recognise anomalies and subtle deviations to normal expectations, focusing attention on critical issues and variables
  • Uses a broad range of features within applications to improve personal productivity including optimising software functions for specific purposes

Unit Mapping Information

Code and title  

current version 

Code and title 

previous version 

Comments 

Equivalence status 

ICTOPN602 Manage dense wavelength division multiplexing transmission system

ICTOPN6125A Manage dense wavelength division multiplexing transmission system

Updated to meet standards for Training Packages

Equivalent unit

Links

Companion Volume implementation guides are found in VETNet - https://vetnet.gov.au/Pages/TrainingDocs.aspx?q=a53af4e4-b400-484e-b778-71c9e9d6aff2

 

Assessment requirements

Modification History

Release 

Comments

Release 1

This version first released with ICT Information and Communications Technology Training Package Version 2.0.

Performance Evidence

Evidence of ability to:

  • determine network parameters and set up performance monitoring
  • manage network using appropriate software and tools
  • monitor network for faults and performance
  • produce fault and performance report
  • analyse performance monitoring and alarm data
  • prepare report with recommendations based on analysis.

Note: If a specific volume or frequency is not stated, then evidence must be provided at least once.

Knowledge Evidence

To complete the unit requirements safely and effectively, the individual must:

  • discuss workplace and industry environment relevant to dense wavelength division multiplexing (DWDM)
  • outline optical communications principles
  • explain DWDM technology, its operation and testing principles
  • summarise simple network management protocol (SNMP)
  • explain organisational policies and procedures relevant to the DWDM
  • determine appropriate report formats and communications tools required to make recommendations on performance and network degradation.

Assessment Conditions

Gather evidence to demonstrate consistent performance in conditions that are safe and replicate the workplace. Noise levels, production flow, interruptions and time variances must be typical of those experienced in the Telecommunications – Optical Networks field of work and include access to:

  • DWDM system and test equipment currently used in industry
  • relevant equipment manuals, software manuals and other procedural documentation.

Assessors of this unit must satisfy the requirements for assessors in applicable vocational education and training legislation, frameworks and/or standards.

Links

Companion Volume implementation guides are found in VETNet - https://vetnet.gov.au/Pages/TrainingDocs.aspx?q=a53af4e4-b400-484e-b778-71c9e9d6aff2